Measurement of Resistance using Potentiometer

Edwiin
Edwiin
Field: Power switch
China

DC Potentiometer Method for Resistance Measurement

The DC potentiometer method is employed to measure low-value unknown resistances by comparing them with a standard resistance. This involves measuring the voltage drops across both the known (standard) and unknown resistances, then determining the unknown resistance through comparison.

To understand this, consider the circuit diagram:

  • R represents the unknown resistance to be measured.

  • S is the standard resistance against which R is compared.

  • A rheostat is used to control the magnitude of the current in the circuit.

A double-pole double-throw (DPDT) switch is incorporated into the circuit. When the switch is moved to position 1, the unknown resistance is connected to the circuit; when shifted to position 2, the standard resistance is connected instead.

Assume that with the switch in position 1, the voltage drop across the unknown resistance is Vᵣ.

and when it is in 2, 2 the voltage drop across the resistance is Vs

On equating the equation (1) and (2), we get

The accuracy of the unknown resistance depends on the value of the standard resistance.

Additionally, it relies on the consistency of the current magnitude during measurements. The circuit yields accurate results only if the current remains unchanged when measuring voltage drops across both resistances. An ammeter is included in the circuit to monitor the current passing through the resistors during readings.The current is adjusted such that the voltage drop across each resistance equals 1 volt.

Give a tip and encourage the author!
Recommended
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis