What is Capacitive Voltage Transformer?

Edwiin
Edwiin
Field: Power switch
China

What is Capacitive Voltage Transformer?

Definition: A capacitive voltage transformer (CVT), also known as a capacitive potential transformer, steps down high - voltage input signals to provide low - voltage signals that can be easily measured by measuring instruments.

The capacitive potential divider, inductive element, and auxiliary transformer are the three main components of a capacitive potential transformer.

CVT.jpg

Why is a Capacitive Voltage Transformer (CVT) Needed?

When measuring high voltages above 100 kV, a highly - insulated transformer is required. Compared with ordinary transformers, highly - insulated transformers are quite costly. To cut costs, capacitive voltage transformers are employed in the system. CVTs are inexpensive, and their performance is not significantly inferior to that of highly - insulated transformers.

Working Principle of Capacitive Voltage Transformer

The capacitive potential divider is used in conjunction with the auxiliary transformer and the inductive element. The capacitive potential divider steps down extra - high - voltage signals to low - voltage signals. The output voltage of the capacitive voltage transformer is further stepped down with the aid of the auxiliary transformer.

Refer to the circuit diagram of the capacitive voltage transformer.

CVT.jpg

Arrangement of Capacitor or Potential Divider

The capacitor or potential divider is connected across the line whose voltage is to be measured or controlled. Suppose C1 and C2 are the capacitors connected across the transmission line. The output of the potential divider serves as the input to the auxiliary transformer.

Compared with the capacitor placed near the transmission line, the capacitor placed near the ground has a higher capacitance value. A high capacitance value means that the impedance of that part of the potential divider becomes low. As a result, low voltages are transmitted to the auxiliary transformer. The auxiliary transformer further steps down the voltages.

N1 and N2 are the number of turns in the primary and secondary windings of the transformer respectively. The meter used to measure the low - voltage value is resistive, while the potential divider is capacitive. Therefore, a phase shift occurs, which affects the output. To solve this problem, an inductor is connected in series with the auxiliary transformer.This inductor L contains the leakage flux of the auxiliary winding of the auxiliary transformer. The value of the inductance is given by

image.png

The value of the inductance is adjustable. The inductance is utilized to compensate for the voltage drops that occur in the transformer due to the decrease in current from the potential divider. However, in practical operation, due to inductance losses, complete compensation cannot be achieved.The voltage transformation ratio of the transformer is expressed as

image.png

Since the value of C1 is larger than that of C2, the value of C1/(C1 + C2) is small, enabling the acquisition of a low voltage.The voltage transformation ratio of the capacitive potential transformer is independent of the burden. Here, the burden refers to the load carried by the secondary winding of the transformer

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
How Does Power Dispatching Ensure Grid Stability and Efficiency?
How Does Power Dispatching Ensure Grid Stability and Efficiency?
Electric Power Dispatching in Modern Power SystemsThe power system is a critical infrastructure of modern society, providing essential electrical energy for industrial, commercial, and residential use. As the core of power system operation and management, electric power dispatching aims to meet electricity demand while ensuring grid stability and economic efficiency.1. Basic Principles of Electric Power DispatchingThe fundamental principle of power dispatching is to balance supply and demand by