What is Creeping in Energy Meter?

Edwiin
Edwiin
Field: Power switch
China

What is Creeping in Energy Meter?

Definition

Creeping in an energy meter is a phenomenon where the aluminium disc rotates continuously when only voltage is applied to the pressure coil and no current flows through the current coil. In essence, it is an error causing the energy meter to consume a minute amount of energy even when no load is connected to the meter.

Impact and Causes of Creeping

Creeping can increase the disc's rotation speed even under light - load conditions, leading to inflated meter readings. Factors such as vibration, stray magnetic fields, and excessive voltage across the potential coil contribute to this phenomenon. The root cause of creeping error often lies in excessive friction. At no - load, the main driving torque is absent, so the disc rotates due to the additional torque from the compensating vane.

Prevention of Creeping

Creeping can be prevented by drilling two holes diametrically opposite each other in the disc. When a small edge of the disc passes under the pole of the magnet, the holes cause the aluminium disc to stop rotating. This effectively limits the disc's revolution. A better understanding of this action can be gained by referring to the figure below.

When a hole in the disc comes under the pole of the magnet, the circular path of the eddy currents in the disc is disrupted. Let (A') denote the center point of the magnetic pole generated by the current. The force exerted on the disc causes the center point (A') to shift away from the axis A of the magnetic pole.At no - load, the disc rotates until the holes align with the edges of the magnet. In this situation, the disc's movement is counteracted by the torque produced.In certain instances, a small piece of iron is affixed to the edge of the disc. An attractive force then arises between the pole magnets and the iron piece, effectively preventing the disc from creeping.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is