What is the reason for disconnecting the DC source before measuring resistance with a multimeter?

Encyclopedia
Field: Encyclopedia
0
China

1. Multimeter Resistance Measurement Principle Related Causes

Multimeter Internal Power Supply Principle

When measuring resistance with a multimeter, an internal battery is used to power the device. The multimeter forms a circuit with the measured resistance through its internal circuitry, and the resistance value is measured according to Ohm's Law. If the DC source is not disconnected, the external power supply will interfere with the measurement loop formed by the multimeter's internal circuit and the measured resistance, leading to inaccurate measurement results. For example, the external DC source may change the current size in the measurement loop, causing the resistance value calculated by the multimeter based on Ohm's Law to deviate from the true value.

Measurement Principles and Circuit Interference

The multimeter measures resistance based on its internal circuit structure and working principle. It provides a known voltage through its internal battery, then measures the current flowing through the measured resistance, and calculates the resistance value according to Ohm's Law (R= V/I ). When an external DC source is connected, it changes the voltage across the measured resistance or the current situation through the resistance. For example, the voltage of the external DC source is superimposed on the voltage provided by the multimeter internally, making the measured current not based on the voltage provided by the multimeter alone, which makes it impossible to accurately measure the resistance value.

II. Causes of Equipment Damage Prevention

Protect the multimeter head

The multimeter's meter head is a relatively precise component. If the DC source is not disconnected during resistance measurement, the external DC source may generate a large current. This current may exceed the range that the multimeter's meter head can withstand, thus damaging the meter head. The meter head is a key component for the multimeter to measure various electrical quantities (including current detection based on internal circuits during resistance measurements). Once damaged, the multimeter will not function properly and requires repair or replacement.

Protect other components in the tested circuit

When measuring resistance without disconnecting the DC source, due to the internal circuit connection of the multimeter during resistance measurement, it may cause other components in the measured circuit to bear abnormal voltage or current. This may damage some components that are sensitive to voltage and current (such as certain semiconductor components), thereby affecting the normal working state of the entire circuit.


Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g