What is the reason for disconnecting the DC source before measuring resistance with a multimeter?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

1. Multimeter Resistance Measurement Principle Related Causes

Multimeter Internal Power Supply Principle

When measuring resistance with a multimeter, an internal battery is used to power the device. The multimeter forms a circuit with the measured resistance through its internal circuitry, and the resistance value is measured according to Ohm's Law. If the DC source is not disconnected, the external power supply will interfere with the measurement loop formed by the multimeter's internal circuit and the measured resistance, leading to inaccurate measurement results. For example, the external DC source may change the current size in the measurement loop, causing the resistance value calculated by the multimeter based on Ohm's Law to deviate from the true value.

Measurement Principles and Circuit Interference

The multimeter measures resistance based on its internal circuit structure and working principle. It provides a known voltage through its internal battery, then measures the current flowing through the measured resistance, and calculates the resistance value according to Ohm's Law (R= V/I ). When an external DC source is connected, it changes the voltage across the measured resistance or the current situation through the resistance. For example, the voltage of the external DC source is superimposed on the voltage provided by the multimeter internally, making the measured current not based on the voltage provided by the multimeter alone, which makes it impossible to accurately measure the resistance value.

II. Causes of Equipment Damage Prevention

Protect the multimeter head

The multimeter's meter head is a relatively precise component. If the DC source is not disconnected during resistance measurement, the external DC source may generate a large current. This current may exceed the range that the multimeter's meter head can withstand, thus damaging the meter head. The meter head is a key component for the multimeter to measure various electrical quantities (including current detection based on internal circuits during resistance measurements). Once damaged, the multimeter will not function properly and requires repair or replacement.

Protect other components in the tested circuit

When measuring resistance without disconnecting the DC source, due to the internal circuit connection of the multimeter during resistance measurement, it may cause other components in the measured circuit to bear abnormal voltage or current. This may damage some components that are sensitive to voltage and current (such as certain semiconductor components), thereby affecting the normal working state of the entire circuit.


Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025