What is the purpose of high resistance in an ammeter?

Encyclopedia
Field: Encyclopedia
0
China

In an ammeter, high resistance serves several important purposes, especially when the ammeter needs to measure large currents or is used in specific circuit configurations. Here are the main purposes of high resistance in an ammeter:

1. Shunt Resistor

When measuring large currents, an ammeter typically cannot handle the entire current directly, as this could damage the ammeter. Therefore, a low-resistance shunt resistor is added to the circuit. The shunt resistor diverts most of the current, allowing only a small portion to pass through the ammeter. This way, the ammeter can safely measure the small current and use a proportional relationship to calculate the total current.

2. Protecting the Ammeter

High resistance can be used to limit the current flowing through the ammeter, preventing excessive current from damaging the ammeter. For example, in precision ammeters, a high resistance is often placed in series with the input to ensure that even in unexpected situations, the current through the ammeter does not exceed its maximum capacity.

3. Voltage Measurement

In some cases, an ammeter can also be used to measure voltage. By placing a high resistance in parallel with the ammeter, the ammeter can be converted into a voltmeter. The current through the high resistance is very small, so it does not significantly affect the total current in the circuit. The ammeter measures the current through the high resistance, indirectly measuring the voltage.

4. Improving Measurement Accuracy

In precision measurements, high resistance can be used to enhance measurement accuracy. By selecting an appropriate high resistance value, measurement errors can be reduced. For example, in measuring very small currents, a high resistance can minimize measurement errors.

5. Adjusting the Range

By connecting different resistance values in series or parallel with the ammeter, the range of the ammeter can be adjusted. For instance, by connecting a low-resistance shunt in parallel, the ammeter's range can be expanded to measure larger currents. By connecting a high resistance in series, the ammeter's range can be narrowed to measure smaller currents.

Summary

High resistance in an ammeter is primarily used for protecting the ammeter, expanding the range, improving measurement accuracy, and enabling voltage measurement. By properly selecting and configuring high resistance, the ammeter can function safely and accurately in various applications.

Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g