What is an Radiation Pyrometer ?

Encyclopedia
Field: Encyclopedia
0
China


What is an Radiation Pyrometer ?


Radiation Pyrometer Definition


A radiation pyrometer is defined as a non-contact temperature sensor that measures temperature by detecting the thermal radiation emitted from an object.


 

Measurement Capability


Radiation pyrometers are particularly useful for measuring high temperatures that are inaccessible or hazardous for traditional contact sensors.


 

Types of Radiation Pyrometers


Fixed Focus Type Radiation Pyrometer



 

 

50d03221-a75a-41ca-a0de-9bf360fc0532.jpg

 

 



Variable Focus Type Radiation Pyrometer





 

29f423d0-1914-46b1-920e-5250d8412b39.jpg


 

 

 

Advantages


  • They can measure high temperatures above 600°C, where other sensors may melt or damage.



  • They do not need physical contact with the object, which avoids contamination, corrosion, or interference.



  • They have a fast speed of response and high output.



  • They are less affected by corrosive atmospheres or electromagnetic fields.


 

Disadvantages


  • These devices may show errors due to non-linear scales, emissivity variations, ambient changes, and contaminants on optical parts.



  • They require calibration and maintenance for accurate readings.



  • They may be expensive and complex to operate.


 

 

Applications


  • Measuring the temperature of furnaces, boilers, kilns, ovens, etc.



  • Measuring the temperature of molten metals, glass, ceramics, etc.



  • Measuring the temperature of flames, plasmas, lasers, etc.



  • Measuring the temperature of moving objects such as rollers, conveyors, wires, etc.


  • Measuring the average temperature of large surfaces such as walls, roofs, pipes, etc.


Give a tip and encourage the author!

Recommended

Classification of Equipment Defects for Relay Protection and Safety Automatic Devices in Substations
In daily operations, various equipment defects are inevitably encountered. Whether maintenance personnel, operation and maintenance staff, or specialized management personnel, all must understand the defect classification system and adopt appropriate measures according to different situations.According to Q/GDW 11024-2013 "Operation and Management Guide for Relay Protection and Safety Automatic Devices in Smart Substations," equipment defects are classified into three levels based on severity an
12/15/2025
Under What Conditions Will the Line Circuit Breaker Auto-Reclosing Signal Be Locked Out?
The line circuit breaker auto-reclosing signal will be locked out if any of the following conditions occur:(1) Low SF6 gas pressure in circuit breaker chamber at 0.5MPa(2) Insufficient energy storage in circuit breaker operating mechanism or low oil pressure at 30MPa(3) Busbar protection operation(4) Circuit breaker failure protection operation(5) Line distance protection zone II or zone III operation(6) Short lead protection operation of circuit breaker(7) Presence of remote tripping signal(8)
12/15/2025
Application of Auto-Reclosing Residual Current Protective Devices in Lightning Protection for Communication Power Supplies
1. Power Interruption Problems Caused by RCD False Tripping During Lightning StrikesA typical communication power supply circuit is shown in Figure 1. A residual current device (RCD) is installed at the power supply input terminal. The RCD primarily provides protection against electrical equipment leakage currents to ensure personal safety, while surge protective devices (SPDs) are installed on power supply branches to protect against lightning intrusions. When lightning strikes occur, the senso
12/15/2025
Reclosing Charge Time: Why Does Reclosing Require Charging? What Effects Does Charging Time Have?
1. Function and Significance of Reclosing ChargingReclosing is a protective measure in power systems. After faults such as short circuits or circuit overloads occur, the system isolates the faulty circuit and then restores normal operation through reclosing. The function of reclosing is to ensure continuous operation of the power system, improving its reliability and safety.Before performing reclosing, the circuit breaker must be charged. For high-voltage circuit breakers, the charging time is g
12/15/2025