Design Challenges in SST Auxiliary Power and Cooling Systems

Dyson
Dyson
Field: Electrical Standards
China

Two Critical and Challenging Subsystems in Solid-State Transformer (SST) Design
Auxiliary Power Supply and Thermal Management System.

Although they do not directly participate in the main power conversion, they serve as the "lifeline" and "guardian" ensuring stable and reliable operation of the main circuit.

Auxiliary Power Supply: The System's "Pacemaker"

The auxiliary power supply provides power for the "brain" and "nerves" of the entire solid-state transformer. Its reliability directly determines whether the system can operate normally.

I. Core Challenges

  • High Voltage Isolation: It must safely extract power from the high-voltage side to supply control and driver circuits on the primary side, requiring the power module to have extremely high electrical isolation capability.

  • Strong Immunity to Interference: The main power circuit’s high-frequency switching (tens to hundreds of kHz) generates large voltage transients (dv/dt) and electromagnetic interference (EMI). The auxiliary power supply must maintain stable output in this harsh environment.

  • Multiple, Precise Outputs:

    • Gate Driver Power: Supplies isolated power to the gate drivers of each power switch (e.g., SiC MOSFETs). Each output must be independent and isolated to prevent crosstalk that could cause shoot-through faults.

    • Control Board Power: Powers digital controllers (DSP/FPGA), sensors, and communication circuits, requiring clean, low-noise power.

II. Typical Power Extraction and Design Approaches

  • High-Voltage Power Extraction: Use an isolated switching power supply (e.g., flyback converter) to extract energy from the high-voltage input. This is the most technically challenging part and requires specialized design.

  • Multi-Output Isolated DC-DC Modules: After obtaining an initial isolated power source, multiple isolated DC-DC modules are typically used to generate additional required isolated voltages.

  • Redundancy Design: In ultra-high reliability applications, the auxiliary power supply may be designed with redundancy to ensure safe shutdown or seamless switchover to a backup supply in case of primary failure.

Thermal Management System: The System's "Air Conditioner"

The thermal management system directly determines the SST’s power density, output capability, and lifespan.

Why is it so critical?

  • Extremely High Power Density: By replacing bulky line-frequency transformers, SSTs concentrate energy into much smaller power modules, leading to a sharp increase in heat flux (heat generated per unit area).

  • Temperature Sensitivity of Semiconductor Devices: Although SiC/GaN power devices offer high efficiency, they have strict junction temperature limits (typically 175°C or lower). Overheating leads to performance degradation, reduced reliability, or permanent failure.

  • Direct Impact on Efficiency: Poor heat dissipation raises chip junction temperature, increasing on-state resistance, which in turn increases losses—creating a vicious cycle.

III. Types of Cooling Methods

Cooling Method Principle Application Scenarios and Features
Natural Convection Heat is dissipated through fins on the heatsink via natural air circulation. Suitable only for low-power or very low-loss experimental setups. Cannot meet the requirements of most SST applications.
Forced Air Cooling A fan is mounted on the heatsink to significantly enhance airflow. The most common and lowest-cost solution. However, heat dissipation capacity is limited, and fans introduce noise, limited lifespan, and dust accumulation issues. Suitable for medium- to low-power density designs.
Liquid Cooling Heat is removed by a liquid cooling plate and circulation pump. The mainstream and preferred choice for high-power-density SSTs today.
Cold Plate Liquid Cooling Power devices are mounted on internal metal plates with fluid channels. Heat dissipation capability is several times that of air cooling; compact structure enables very low temperature at the heat source.
Immersion Cooling The entire power module is submerged in an insulating coolant. Highest heat dissipation efficiency; non-boiling single-phase immersion vs. boiling two-phase immersion. Capable of handling extreme power densities, but system complexity and cost are highest.

3. Advanced Thermal Management Concepts

3.1 Predictive Thermal Control
The system monitors temperature and load in real-time, predicts future temperature rise trends, and preemptively adjusts fan speeds, pump rates, or even slightly reduces output power to prevent temperatures from reaching critical levels.

3.2 Electro-Thermal Co-Design
Thermal design is synchronized with electrical and structural design from the early stages of development. For example, simulations are used to optimize the layout of power modules, ensuring that high heat flux components are preferentially placed near the coolant inlet.

4. The Lifeline System Working in Concert

Auxiliary power supplies and thermal management systems together form the core safeguards of a solid-state transformer. Their relationship can be summarized as follows:

4.1 The Auxiliary Power Supply - Ensuring System Operability
It is the prerequisite for ensuring that the system "can operate," providing power to all control units, including those of the thermal management system (fans, water pumps).

4.2 The Thermal Management System - Ensuring System Durability
It is the cornerstone for ensuring that the system "can sustain operation," safeguarding main power devices and the auxiliary power supply itself from failure due to overheating.

A highly reliable SST is inevitably the result of a perfect integration of outstanding electrical design, thermal management, and control design.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Why is it difficult to increase the voltage level?
Why is it difficult to increase the voltage level?
The solid-state transformer (SST), also known as a power electronic transformer (PET), uses voltage level as a key indicator of its technological maturity and application scenarios. Currently, SSTs have reached voltage levels of 10 kV and 35 kV on the medium-voltage distribution side, while on the high-voltage transmission side, they remain in the stage of laboratory research and prototype validation. The table below clearly illustrates the current status of voltage levels across different appli
Echo
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.