What is an Air Switch?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China


What is an Air Switch?


Air circuit breaker definition


Air circuit breaker is a kind of high voltage circuit breaker which uses air as arc extinguishing medium. Compared with other types of high-voltage circuit breakers such as SF6 circuit breakers and vacuum circuit breakers, air circuit breakers are usually suitable for lower voltage levels of power systems.


Constituent structure


  • Auxiliary contact

  • Alarm contact

  • Shunt release

  • Undervoltage release

  • Electric operating mechanism

  • Turning handle

  • Extension handle

  • Handle locking device


Working principle


The working principle of the air circuit breaker is based on the arc extinguishing characteristics of the air. When the circuit breaker needs to disconnect the circuit, the moving contacts and the static contacts are separated in the air, and the arc between the contacts is generated in the air. Because the air has a certain insulating strength, the arc is gradually extinguished in the process of separating the contacts, thus cutting off the current. When the circuit needs to be closed again, the contacts re-contact and the circuit recovers.



Working condition


Ambient air temperature: ambient air temperature upper limit +40℃; Ambient air temperature limit -5℃; The average ambient air temperature for 24h does not exceed +35℃.


Elevation: The elevation of the installation site does not exceed 2000m.


Atmospheric conditions: the relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40℃; It can have higher relative humidity at lower bottom temperature. The monthly average maximum relative humidity of the wettest month is 90%, while the monthly average minimum temperature of the month is +25 ° C, taking into account the condensation that occurs on the surface of the product due to temperature changes.


Pollution level: Pollution level is 3.


Advantage


  • Lower cost

  • Simple structure

  • Environmental protection

  • Scope of application

  • Arc extinguishing capability


Application scenario


Power distribution system: used to control and protect medium and low voltage power distribution lines.


Industrial facilities: Used to protect small and medium-sized motors and power equipment.


Building power distribution: Used for power distribution systems within buildings.


Small power stations: For the transmission and distribution of electricity in small power stations.


Sum up


Air circuit breaker is a commonly used electrical protection equipment, with simple structure, easy installation, easy operation and relatively low price characteristics, widely used in household, commercial and industrial electricity and other fields. When selecting and using air circuit breakers, appropriate products should be selected according to actual needs, and attention should be paid to correct installation and maintenance to ensure the safe and stable operation of the power system.


Give a tip and encourage the author!
Recommended
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
Based on years of field statistics on switchgear accidents, combined with analysis focusing on the circuit breaker itself, the main causes have been identified as: failure of operation mechanism; insulation faults; poor breaking and closing performance; and poor conductivity.1.Failure of Operation MechanismFailure of operation mechanism manifests as delayed operation or unintended operation. Since the most basic and important function of a high-voltage circuit breaker is to operate correctly and
Felix Spark
11/04/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Compact Air-Insulated RMUs for Retrofit & New Substations
Compact Air-Insulated RMUs for Retrofit & New Substations
Air-insulated ring main units (RMUs) are defined in contrast to compact gas-insulated RMUs. Early air-insulated RMUs used vacuum or puffer-type load switches from VEI, as well as gas-generating load switches. Later, with the widespread adoption of the SM6 series, it became the mainstream solution for air-insulated RMUs. Similar to other air-insulated RMUs, the key difference lies in replacing the load switch with an SF6-encapsulated type—where the three-position switch for load and grounding is
Echo
11/03/2025
Climate-Neutral 24kV Switchgear for Sustainable Grids | Nu1
Climate-Neutral 24kV Switchgear for Sustainable Grids | Nu1
Expected service life of 30–40 years, front access, compact design equivalent to SF6-GIS, no SF6 gas handling – climate-friendly, 100% dry air insulation. The Nu1 switchgear is metal-enclosed, gas-insulated, featuring a withdrawable circuit breaker design, and has been type-tested according to relevant standards, approved by the internationally recognized STL laboratory.Compliance Standards Switchgear: IEC 62271-1 High-voltage switchgear and controlgear – Part 1: Common specifications for altern
Edwiin
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.