Faults and Treatments during the Installation and Debugging of Electrical Equipment in Substations

Edwiin
Edwiin
Field: Power switch
China

The arc chutes serve several key functions:

  • Arc Convection - Based Motion, Elongation, and Cooling: Facilitate the movement of the arc, extend its length, and dissipate heat through convection.

  • Arc Compression: Squeeze the arc between the insulating sidewalls, altering its physical characteristics.

  • Gas - Assisted Arc Cooling: Cool the arc by leveraging the gassing properties of the wall materials.

  • Arc Segmentation: Split the arc into multiple shorter, series - connected arcs using metal plates.

  • Arc Length Augmentation: Increase the arc length by employing isolating plates as barriers.

Typically, an arc chute utilizes at least two of these functions in combination.

There are two fundamental types of arc chutes, distinguished mainly by the material of the arc plates:

  • Metal - Plate Arc Chutes

  • Insulating - Plate Arc Chutes

Metal - plate arc chutes break the arc into a series of shorter arcs that burn between a set of parallel plates. Steel is commonly used for these metal plates due to its ferromagnetic nature. This property helps attract the arc and keep it confined within the stack of plates. In this type of arc chute, diverging arc runners, which are essentially a pair of specially designed arc horns, initially guide the arc into the plates. Subsequently, the electromagnetic forces generated by the current loop propel the arc deeper into the chute.A schematic diagram of this type of arc chute (Deion chamber) is illustrated in Figure.

Give a tip and encourage the author!
Recommended
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
Based on years of field statistics on switchgear accidents, combined with analysis focusing on the circuit breaker itself, the main causes have been identified as: failure of operation mechanism; insulation faults; poor breaking and closing performance; and poor conductivity.1.Failure of Operation MechanismFailure of operation mechanism manifests as delayed operation or unintended operation. Since the most basic and important function of a high-voltage circuit breaker is to operate correctly and
Felix Spark
11/04/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Compact Air-Insulated RMUs for Retrofit & New Substations
Compact Air-Insulated RMUs for Retrofit & New Substations
Air-insulated ring main units (RMUs) are defined in contrast to compact gas-insulated RMUs. Early air-insulated RMUs used vacuum or puffer-type load switches from VEI, as well as gas-generating load switches. Later, with the widespread adoption of the SM6 series, it became the mainstream solution for air-insulated RMUs. Similar to other air-insulated RMUs, the key difference lies in replacing the load switch with an SF6-encapsulated type—where the three-position switch for load and grounding is
Echo
11/03/2025
Climate-Neutral 24kV Switchgear for Sustainable Grids | Nu1
Climate-Neutral 24kV Switchgear for Sustainable Grids | Nu1
Expected service life of 30–40 years, front access, compact design equivalent to SF6-GIS, no SF6 gas handling – climate-friendly, 100% dry air insulation. The Nu1 switchgear is metal-enclosed, gas-insulated, featuring a withdrawable circuit breaker design, and has been type-tested according to relevant standards, approved by the internationally recognized STL laboratory.Compliance Standards Switchgear: IEC 62271-1 High-voltage switchgear and controlgear – Part 1: Common specifications for altern
Edwiin
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.