Digitalicition example based by IEC 61850 in medium voltage switchgear

Edwiin
Edwiin
Field: Power switch
China

The utilization of Rogowski coils for current measurements, voltage dividers for voltage measurements, and a digital bus for sharing switchgear events and sampled measured values enables the separation of measuring hardware engineering from protection applications. This decoupling enhances flexibility and efficiency in electrical system design and operation.

For the protection functions of each Intelligent Electronic Device (IED), line - to - ground currents are consistently measured separately in every feeder. In incoming feeders, resistive dividers are connected to the cables, supplying the necessary voltage measurements to the IEDs within these feeders.

Outgoing feeder protection schemes often require the use of busbar voltage measurements. For example, in section A, one outgoing feeder is equipped with resistive voltage dividers linked to the section A busbar system. Additionally, a bus coupler in this setup has resistive voltage dividers connected to the section B busbar system.

The IEDs in these feeders not only potentially utilize the measured voltage for their own protection schemes but also publish voltage - sampled measured data to the digital communication network. This allows all other IEDs, whether located in section A or B, to subscribe to this digital voltage measurement for their specific protection requirements.

Finally, switchgear events are shared across all feeders, which is crucial for implementing switchgear control, blocking, and interlocking logic. This sharing of information ensures coordinated and reliable operation of the switchgear, enhancing the overall safety and stability of the electrical system.

Give a tip and encourage the author!
Recommended
What are the safety precautions and guidelines for using AC load banks?
What are the safety precautions and guidelines for using AC load banks?
AC load banks are electrical devices used to simulate real-world loads and are widely applied in power systems, communication systems, automation control systems, and other fields. To ensure personal and equipment safety during use, the following safety precautions and guidelines must be observed:Select an appropriate AC load bank: Choose an AC load bank that meets actual requirements, ensuring its capacity, voltage rating, and other parameters satisfy the intended application. Additionally, sel
Echo
11/06/2025
What should be noted when installing a Type K thermocouple?
What should be noted when installing a Type K thermocouple?
Installation precautions for Type K thermocouples are critical to ensuring measurement accuracy and extending service life. Below is an introduction to the installation guidelines for Type K thermocouples, compiled from highly authoritative sources:1.Selection and Inspection Select the appropriate thermocouple type: Choose the right thermocouple based on the temperature range, medium properties, and required accuracy of the measurement environment. Type K thermocouples are suitable for temperatu
James
11/06/2025
 Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes and Preventive Measures of Fire and Explosion in Oil Circuit Breakers
Causes of Fire and Explosion in Oil Circuit Breakers When the oil level in an oil circuit breaker is too low, the oil layer covering the contacts becomes too thin. Under the effect of the electric arc, the oil decomposes and releases flammable gases. These gases accumulate in the space beneath the top cover, mixing with air to form an explosive mixture, which can ignite or explode under high temperature. If the oil level inside the tank is too high, the released gases have limited space to expan
Felix Spark
11/06/2025
LTB vs DTB vs GIS: HV Circuit Breaker Comparison
LTB vs DTB vs GIS: HV Circuit Breaker Comparison
The basic meaning of a high-voltage circuit breaker is, simply put, that under normal conditions, it is used to open (interrupt, trip) and close (make, reclose) circuits, feeders, or specific loads—such as those connected to transformers or capacitor banks. When a fault occurs in the power system, protective relays activate the circuit breaker to interrupt either load current or short-circuit current, thereby ensuring the safe operation of the power system.A high-voltage circuit breaker is a typ