Temperature-Rise test of Large Capacity Generator Circuit Breaker

Edwiin
Edwiin
Field: Power switch
China

The temperature rise test is a crucial test for generator circuit breakers to verify their current - carrying capacity. In this test, the maximum test current can reach as high as 35 kA to simulate the real operating environment. The test sample is a complete three - phase installation, but the test is only conducted on a single phase. The air temperature can be adjusted using cooling water.
The implementation of this test mainly focuses on the following three aspects, and the layout of the experimental site is shown in the figure. The following points should be noted during this test:

1.Attention to the Test Loop and Sample Resistance under High - Current Testing
Under high - current test conditions, it is essential to pay close attention to the test loop and the resistance of the sample. To avoid excessive voltage drops, it is necessary to reduce the current - carrying capacity of the connecting cables, select test equipment with appropriate capacities, and enhance the port voltage output capacity.

2. Appropriate Layout of the Test Loop
Using an appropriate test loop layout can effectively reduce the total power - frequency electrical impedance during operation. It can also prevent issues such as the skin effect, hysteresis losses, and heat generation in the test circuit body caused by multi - wire connections, which could otherwise affect the normal progress of the temperature rise test.

3. Temperature Adjustment under Forced Air - Cooling Test Conditions
Under forced air - cooling test conditions, since the adjustment of the wind temperature is achieved through heat exchange with the water temperature, there is a time lag. Therefore, adjustments should be made based on the temperature limits. It is necessary to make slow adjustments within the allowable temperature range to ensure accurate control of the test environment.

Give a tip and encourage the author!
Recommended
What are the causes of dielectric withstand failure in vacuum circuit breakers?
What are the causes of dielectric withstand failure in vacuum circuit breakers?
Causes of Dielectric Withstand Failure in Vacuum Circuit Breakers: Surface contamination: The product must be thoroughly cleaned before dielectric withstand testing to remove any dirt or contaminants.Dielectric withstand tests for circuit breakers include both power-frequency withstand voltage and lightning impulse withstand voltage. These tests must be performed separately for phase-to-phase and pole-to-pole (across the vacuum interrupter) configurations.Circuit breakers are recommended to be t
Felix Spark
11/04/2025
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
Based on years of field statistics on switchgear accidents, combined with analysis focusing on the circuit breaker itself, the main causes have been identified as: failure of operation mechanism; insulation faults; poor breaking and closing performance; and poor conductivity.1.Failure of Operation MechanismFailure of operation mechanism manifests as delayed operation or unintended operation. Since the most basic and important function of a high-voltage circuit breaker is to operate correctly and
Felix Spark
11/04/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Compact Air-Insulated RMUs for Retrofit & New Substations
Compact Air-Insulated RMUs for Retrofit & New Substations
Air-insulated ring main units (RMUs) are defined in contrast to compact gas-insulated RMUs. Early air-insulated RMUs used vacuum or puffer-type load switches from VEI, as well as gas-generating load switches. Later, with the widespread adoption of the SM6 series, it became the mainstream solution for air-insulated RMUs. Similar to other air-insulated RMUs, the key difference lies in replacing the load switch with an SF6-encapsulated type—where the three-position switch for load and grounding is
Echo
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.