Rogowski Coil application in GIS

Edwiin
Edwiin
Field: Power switch
China

Rogowski coils offer highly accurate secondary outputs without the risk of saturation since they do not incorporate an iron core. The air - core design ensures linear measurement, although it generates only a relatively small voltage (1V as opposed to 100V). This characteristic enables a compact equipment layout and allows for easy integration into Gas - Insulated Switchgear (GIS) with minimal space requirements due to the absence of an iron core. Additionally, Rogowski coils exhibit high immunity to noise and surge voltages because their coupling factor is significantly lower than that of coils with an iron core.

In a GIS enclosure, the primary conductor functions as the primary winding of the Rogowski coil. The secondary winding of the coil, which has an air core, is connected to an analog - to - digital converter within an Intelligent Electronic Device (IED). Subsequently, it is linked to the protection and control system via an optical bus. The primary conductor, operating at a high - voltage potential, carries the current and serves as the primary winding of the Rogowski coil.

The secondary windings are at ground potential within the GIS enclosure. Their role is to transform the current in the primary conductor into an induced voltage in the secondary windings of the Rogowski coil. As shown in the photo, an electronic card then converts the measured value into a digital signal for connection to the control system.

Give a tip and encourage the author!
Recommended
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
What are the causes of failures in low-voltage switchgear circuit breakers themselves?
Based on years of field statistics on switchgear accidents, combined with analysis focusing on the circuit breaker itself, the main causes have been identified as: failure of operation mechanism; insulation faults; poor breaking and closing performance; and poor conductivity.1.Failure of Operation MechanismFailure of operation mechanism manifests as delayed operation or unintended operation. Since the most basic and important function of a high-voltage circuit breaker is to operate correctly and
Felix Spark
11/04/2025
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Compact Air-Insulated RMUs for Retrofit & New Substations
Compact Air-Insulated RMUs for Retrofit & New Substations
Air-insulated ring main units (RMUs) are defined in contrast to compact gas-insulated RMUs. Early air-insulated RMUs used vacuum or puffer-type load switches from VEI, as well as gas-generating load switches. Later, with the widespread adoption of the SM6 series, it became the mainstream solution for air-insulated RMUs. Similar to other air-insulated RMUs, the key difference lies in replacing the load switch with an SF6-encapsulated type—where the three-position switch for load and grounding is
Echo
11/03/2025
Climate-Neutral 24kV Switchgear for Sustainable Grids | Nu1
Climate-Neutral 24kV Switchgear for Sustainable Grids | Nu1
Expected service life of 30–40 years, front access, compact design equivalent to SF6-GIS, no SF6 gas handling – climate-friendly, 100% dry air insulation. The Nu1 switchgear is metal-enclosed, gas-insulated, featuring a withdrawable circuit breaker design, and has been type-tested according to relevant standards, approved by the internationally recognized STL laboratory.Compliance Standards Switchgear: IEC 62271-1 High-voltage switchgear and controlgear – Part 1: Common specifications for altern
Edwiin
11/03/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.