Bundled Conductors Used in Transmission Line

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Are Bundled Conductors Used In Transmission Line

Single stranded conductors are used in transmission system usually up to 220 KV. But it is not possible to use single-stranded conductor for the voltage above 220 KV systems. For very high voltage system, hollow conductor can be used to optimize the flow of current through it. But erection and maintenance of hollow conductors in the ∑HV system are not economical. The problem can be solved by using bundled conductors instead of hollow conductor in the electrical transmission system above 220 KV voltage level.

What is Bundled Conductor?

We call bundled conductor to those conductors which form from two or more stranded conductors, bundled together to get more current carrying capacity.

Here, we use two or more stranded conductors per phase. Also, to increase the current carrying capacity of the system, a bundle conductor also contributes various facilities to the electrical transmission system. A bundled conductor reduces the reactance of the electric transmission line. It also reduces voltage gradient, corona loss, radio interference, surge impedance of the transmission lines.
By making bundle conductor, the geometric mean radius (GMR) of the conductor increased. As the self GMR of the conductor increases, the
inductance of the conductor decreases. Theoretically, there is an optimum sub-conductor spacing in bundle conductor that will give minimum voltage gradient on the surface of bundle conductor. The optimum spacing between sub-conductors for reducing voltage gradient is eight to ten times of the diameter of the conductor.

Since the voltage gradient gets reduced, the radio interference also gets reduced.
As the inductance of the bundled conductor is reduced, the surge impedance of the line is reduced became the formula of surge impedance is

Where L is the inductance per phase per unit length, and C is the capacitance per phase per unit length of the transmission line. As the surge impedance gets reduced due to bundling the conductor, the surge impedance loading, of the conductor gets increased. Increased surge impedance loading makes the transmission capacity of the system more.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.