• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Admittance: What is it? (Formula & Admittance vs Impedance)

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Is Admittance

What is Admittance?

Admittance is defined as a measure of how easily a circuit or device will allow current to flow through it. Admittance is the reciprocal (inverse) of impedance, akin to how conductance and resistance are related. The SI unit of admittance is the siemens (symbol S).

To reiterate the above definition: let us first go through some important terms which associated with the topic admittance. We all know that resistance (R) has only magnitude but no phase. We can say that it is the measure of opposition for the flow of current.

In an AC circuit; in addition to the resistance, two impeding mechanisms (inductance and capacitance) have to be considered. So the term impedance is introduced which have the same function of resistance but have both magnitude and phase. Its real part is resistance, and the imaginary part is reactance, which came from the impeding mechanism.

When looking at admittance vs impedance, admittance is the inverse (i.e. the reciprocal) of impedance. Therefore it has the opposite function of impedance. That is, we can say it is the measure of the flow of current which is allowed by a device or a circuit. Admittance also measures the dynamic effects of susceptance of a material to polarization and is measured in Siemens or Mho. Oliver Heaviside introduced this in December 1887.

Derivation of Admittance from Impedance

Impedance consists of real part (resistance) and imaginary part (reactance). The symbol for impedance is the Z symbol, and the symbol for admittance is the Y symbol.

Admittance is also a complex number as impedance which is having a real part, Conductance (G) and imaginary part, Susceptance (B).

(it is negative for capacitive susceptance and positive for inductive susceptance)

Admittance Triangle

It is formed by admittance (Y), susceptance (B) and conductance (G) as shown below.
admittance triangle

From admittance triangle,

Admittance of a Series Circuit

When a circuit consist of Resistance and Inductance reactance in series is considered as shown below.
admittance series circuit

When the circuit consist of Resistance and Capacitive reactance in series is considered as shown below.
admittance

Admittance of a Parallel Circuit

A circuit which consist of two branches say A and B are considered as shown in figure below. ‘A’ comprises of an inductive reactance, XL and a resistance, R1 and ‘B’ comprises of a capacitive reactance, XC and a resistance, R2. The voltage, V is applied to the circuit.
admittance parallel circuitFor Branch A
For Branch B


So, if the admittance of a circuit is known, then the total current and power factor can be obtained easily.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.