Is the resistance higher in solid or stranded (copper) wire?

Encyclopedia
Encyclopedia
Field: Encyclopedia
0
China

Solid wire and stranded wire are both commonly used types of conductors, each with their own advantages and disadvantages. When discussing resistance, we need to consider factors such as the total cross-sectional area, material, temperature, and the geometric shape of the conductor. Below is some basic information about the resistance characteristics of solid wire and stranded wire:

Solid Wire

Solid wire is made from a single piece of metal conductor without any internal gaps or seams. This type of wire is typically used for fixed connections, such as wires inside wall sockets or situations where frequent bending is not required.

Resistance Characteristics

  • Lower Resistance: For the same cross-sectional area, solid wire generally has lower resistance compared to stranded wire because solid wire does not have the gaps present in stranded wire.

  • Temperature Coefficient: The resistance changes with temperature, but the temperature coefficient is the same for both solid and stranded wire.

Stranded Wire

Stranded wire consists of multiple fine metal strands twisted together. These strands can move independently of one another. This type of wire is typically used in applications that require frequent bending, such as cables or internal wiring in equipment.

Resistance Characteristics

  • Higher Resistance: Due to the presence of gaps within stranded wire, its total cross-sectional area is actually less than that of a solid wire of the same nominal size. Therefore, stranded wire has slightly higher resistance compared to solid wire at the same nominal cross-sectional area.

  • Skin Effect: In high-frequency applications, stranded wire can reduce the skin effect, where current flows predominantly on the surface of the conductor. The design of stranded wire exposes more surface area, thereby reducing the resistance at high frequencies.

Considerations in Practical Applications

While stranded wire has slightly higher resistance at the same nominal cross-sectional area, it offers several advantages in practical applications:

  1. Flexibility: Stranded wire is more flexible and easier to bend, making it suitable for applications requiring frequent movement or bending.

  2. Tensile Strength: Stranded wire has better tensile strength and is less likely to break.

  3. Vibration Resistance: Stranded wire performs better in vibrating environments and is less likely to be damaged due to repeated mechanical stress.

Summary

For the same nominal cross-sectional area, solid wire generally has lower resistance compared to stranded wire due to the absence of internal gaps. However, in high-frequency applications, the design of stranded wire can reduce the skin effect, thus performing better at high frequencies. Additionally, stranded wire offers significant advantages in terms of flexibility, tensile strength, and vibration resistance, making it suitable for applications that require frequent bending or are subject to vibration. Therefore, when choosing between conductor types, it is important to balance resistance, flexibility, and mechanical strength based on the specific application requirements.


Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
Why Monitoring Accuracy Matters in Power Quality Systems
Why Monitoring Accuracy Matters in Power Quality Systems
The Critical Role of Monitoring Accuracy in Power Quality Online DevicesThe measurement accuracy of online power quality monitoring devices is the core of the power system’s “perception capability,” directly determining the safety, economy, stability, and reliability of power supply to users. Inadequate accuracy leads to misjudgment, incorrect control, and flawed decision-making—potentially causing equipment damage, economic losses, or even grid failures. Conversely, high accuracy enables precis
Oliver Watts
10/30/2025
How Does Power Dispatching Ensure Grid Stability and Efficiency?
How Does Power Dispatching Ensure Grid Stability and Efficiency?
Electric Power Dispatching in Modern Power SystemsThe power system is a critical infrastructure of modern society, providing essential electrical energy for industrial, commercial, and residential use. As the core of power system operation and management, electric power dispatching aims to meet electricity demand while ensuring grid stability and economic efficiency.1. Basic Principles of Electric Power DispatchingThe fundamental principle of power dispatching is to balance supply and demand by