Testing of Electrical Power Cable | Type Test | Acceptance Test | Routine Test

Electrical4u
Electrical4u
Field: Basic Electrical
0
China

What Is Testing Of Electrical Power Cable

  1. The following tests are the type test of electrical power cable.

    Physical tests for insulation and sheath

    1. Tensile strength and elongation at break

    2. Aging in an air oven

    3. Aging in air bomb

    4. Aging in an oxygen bomb

    5. Hot set

    6. Oil resistance

    7. Tear resistance


    8. Insulation resistance

    9. High voltage (water immersion) test

    10. Flammability test (only for SE-3, SE-4)

    11. Water abortion test (for insulation)

    12. Persulphate test (for copper )

    13. Annealing test (for copper)

    14. Tensile test (for Aluminium)

    15. Wrapping test (for Aluminium)

    16. Conductor resistance test (for all)

    17. Test for thickness of insulation (for all)

    18. Measurement of overall diameter (where specified)(for all)


  2. Acceptance test: The following shall constitute acceptance test:

    1. Annealing test (for copper)

    2. Tensile test (for Aluminium )

    3. Wrapping test (for Aluminium )

    4. Conductor resistance test

    5. Test for the thickness of insulation and sheath and overall diameter

    6. Tensile strength and elongation at break of insulation and heath

    7. Hot set test for insulation and sheath

    8. High voltage test

    9. Insulation resistance test

  3. Routine test: The following shall constitute the routine test.

    1. Conductor resistance test

    2. High voltage test

    3. Insulation resistance test

High Voltage Test (Water Immersion Test) :
Approximate 3 meters long core is removed as a sample from the finished cable or cord. The sample then is so immersed in a water bath at room temperature that its ends protrude at least 200 mm above the water level. After 24 hours, an alternating voltage of the required level is applied between
conductor and water. This voltage is raised as per requirement within 10 sec and hold constant at this value for 5 min. If the sample fails in this test, one more sample can be subjected to this test.

Test on completed cables (Acceptance and routine test) :
This test shall be carried out between conductors or between conductor and screen/armor. The test shall be carried out on required voltage the test shall be carried out at room temperature and the time of application shall be 5 min no failure of Insulation shall occur.

Flammability Test :
Period of burning after removal of the flame shall not exceed 60 sec and the unaffected portion from the lower edge of the top clamp shall be at least 50 mm.

Statement: Respect the original, good articles worth sharing, if there is infringement please contact delete.

Give a tip and encourage the author!
Recommended
THD Measurement Error Standards for Power Systems
THD Measurement Error Standards for Power Systems
Error Tolerance of Total Harmonic Distortion (THD): A Comprehensive Analysis Based on Application Scenarios, Equipment Accuracy, and Industry StandardsThe acceptable error range for Total Harmonic Distortion (THD) must be evaluated based on specific application contexts, measurement equipment accuracy, and applicable industry standards. Below is a detailed analysis of key performance indicators in power systems, industrial equipment, and general measurement applications.1. Harmonic Error Standar
Edwiin
11/03/2025
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Busbar-Side Grounding for 24kV Eco-Friendly RMUs: Why & How
Solid insulation assistance combined with dry air insulation is a development direction for 24 kV ring main units. By balancing insulation performance and compactness, the use of solid auxiliary insulation allows passing insulation tests without significantly increasing phase-to-phase or phase-to-ground dimensions. Encapsulation of the pole can address the insulation of the vacuum interrupter and its connected conductors.For the 24 kV outgoing busbar, with the phase spacing maintained at 110 mm,
Dyson
11/03/2025
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
How Vacuum Tech Replaces SF6 in Modern Ring Main Units
Ring main units (RMUs) are used in secondary power distribution, directly connecting to end-users such as residential communities, construction sites, commercial buildings, highways, etc.In a residential substation, the RMU introduces 12 kV medium voltage, which is then stepped down to 380 V low voltage through transformers. The low-voltage switchgear distributes electrical energy to various user units. For a 1250 kVA distribution transformer in a residential community, the medium-voltage ring m
James
11/03/2025
What Is THD? How It Affects Power Quality & Equipment
What Is THD? How It Affects Power Quality & Equipment
In the field of electrical engineering, the stability and reliability of power systems are of paramount importance. With the advancement of power electronics technology, the widespread use of nonlinear loads has led to an increasingly serious problem of harmonic distortion in power systems.Definition of THDTotal Harmonic Distortion (THD) is defined as the ratio of the root mean square (RMS) value of all harmonic components to the RMS value of the fundamental component in a periodic signal. It is
Encyclopedia
11/01/2025
Related Products
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.