• 100kVA 120kVA 150KVA 315kVA 630kVA Neutral Grounding/earthing Transformer Dry Type Power Transformer
100kVA 120kVA 150KVA 315kVA 630kVA Neutral Grounding/earthing Transformer Dry Type Power Transformer
discuss personally
Model
DKSC-11-630
Basic info
Brand ROCKWILL
Model NO. 100kVA 120kVA 150KVA 315kVA 630kVA Neutral Grounding/earthing Transformer Dry Type Power Transformer
Rated voltage 11kV
Rated frequency 50/60Hz
Rated capacity 630kVA
Series DKSC
Product Detail

Description

100-630kVA neutral grounding dry-type power transformers with epoxy resin casting offer excellent insulation, fireproof and moisture-proof capabilities. By establishing neutral points, they efficiently connect arc suppression coils or grounding resistors to quickly suppress grid grounding fault currents, enhancing power supply reliability. Suitable for 10kV/35kV distribution networks, data centers, commercial buildings, etc.

 Product Advantages:

Designed to excel in demanding power distribution scenarios, our transformers integrate cutting-edge technology to deliver unmatched reliability and performance.

  • Ultra-low Partial Discharge: With a partial discharge level ≤ 10 pC, our transformers minimize electrical stress and insulation degradation, ensuring stable long-term operation and reducing the risk of premature failure.

  • Extreme Cold Adaptability: Capable of operating at low temperatures down to -25°C, these transformers maintain reliable performance in harsh environments, making them ideal for cold regions and outdoor installations.

  • Superior Performance Classifications: Rated at E3 (Exceptional Aging Resistance), C3 (High Contamination Resistance), and F1 (Low Noise Emission), our products meet the highest industry standards for durability, adaptability, and environmental compatibility.

  • Minimal Temperature Rise: Engineered to achieve a low temperature rise (100K - 125K) even under heavy loads, these transformers optimize energy efficiency, extend service life, and reduce maintenance requirements.

  • Robust Electrical Tolerance: Designed with high impulse voltage withstand capabilities, our transformers can endure sudden electrical surges and transient overvoltages, while their exceptional short-circuit tolerance ensures safe operation during fault conditions, safeguarding both equipment and power systems.

Main technical specifications

The following table details the key technical specifications of the product, comprehensively covering electrical performance, mechanical characteristics, and dimensional parameters to provide a clear reference for technical selection and application scenarios.

 

 

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec