10kV overhead insulated cable

  • 10kV overhead insulated cable

Key attributes

Brand Wone Store
Model NO. 10kV overhead insulated cable
Rated voltage 10kV
Rated frequency 50/60Hz
Series JKLYJ

Product descriptions from the supplier

Description

Product use

This product is suitable for transmission and distribution lines with AC rated voltage of 10kV and below, and is used to transmit power on overhead transmission lines.

Implementation standards

This product implements GB/T 14049-2008, Q/0900 TKD001-2022, Q/0900 TKD009-2017.

 Characteristics of use

  • The maximum long-term temperature allowed for the conductor during normal operation of the cross-linked polyethylene insulated overhead cable is 90 °C, and the maximum temperature allowed for the cable conductor is 250 °C in the event of a short circuit (the maximum duration does not exceed 5s);

  • The minimum allowable laying temperature of the cable is not less than -20°C;

  • Bending requirements for overhead insulated cables:

The minimum bending radius of single-core cable is 20 (D+d) ±5%;

The minimum bending radius of multi-core cable is 15 (D+d) ±5%.

Note: D is the actual outer diameter of the cable, and d is the actual outer diameter of the cable conductor

 Product model specifications

 Product model

Model

name

JKYJ

Copper-core XLPE insulated overhead cable

JKTRYJ

Soft copper core XLPE insulated overhead cable

JKLYJ

Aluminum-core cross-linked polyethylene insulated overhead cable

JKLHYJ

Aluminum alloy core XLPE insulated overhead cable

JKLGYJ

Steel core aluminum stranded core XLPE insulated overhead cable

JKLYJ/Q

Aluminum-core lightweight XLPE thin insulated aerial cable

JKLHYJ/Q

Aluminum alloy core lightweight XLPE thin insulated overhead cable

Product specifications

Model

Number of cores

Nominal cross-section/mm2

JKYJ、JKLYJ、JKTRYJ、JKLHYJ

1

10~400

3

25~400

JKLYJ/Q、JKLHYJ/Q

1

10~400

JKLGYJ

1

50/8~240/30

Product performance indicators

Conductor DC resistance

Nominal cross-section/
mm2

Maximum Conductor Resistance at 20°C/(Ω/km)

copper

Soft copper

aluminium

Aluminum alloy

25

0.749

0.727

1.200

1.393

35

0.540

0.524

0.868

1.007

50

0.399

0.387

0.641

0.744

70

0.276

0.268

0.443

0.514

95

0.199

0.193

0.320

0.371

120

0.158

0.153

0.253

0.294

150

0.128

/

0.206

0.239

185

0.1021

/

0.164

0.190

240

0.0777

/

0.125

0.145

300

0.0619

/

0.100

0.116

400

0.0484

/

0.0778

0.0904

Cable tearing force

Nominal section mm2

Single-core cable breaking force/N

Hard copper

aluminium

Aluminum alloy

10

3471

1650

2514

16

5486

2517

4022

25

8465

3762

6284

35

11731

5177

8800

50

16502

7011

12569

70

23461

10354

17596

95

31759

13727

23880

120

39911

17339

30164

150

49505

21033

37706

185

61846

26732

46503

240

79823

34679

60329

300

99788

43349

75411

400

133040

55707

100548

AC voltage test

Rated voltage U/kV

10

Ordinary insulating structure

Lightweight and thin insulated structure

Test voltage/kV

18

12

Duration/min

1

Performance requirements:

No breakdown

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.