10kV Three-phase Oil-immersed Three-lysed Rectifier Transformer

  • 10kV Three-phase Oil-immersed Three-lysed Rectifier Transformer

Key attributes

Brand ROCKWILL
Model NO. 10kV Three-phase Oil-immersed Three-lysed Rectifier Transformer
Rated voltage 11kV
Rated frequency 50/60Hz
Rated capacity 1500kVA
Series ZSF

Product descriptions from the supplier

Description

Product Description

This 10kV Three-phase Oil-immersed Three-lysed Rectifier Transformer is a specialized power conversion solution engineered for ultra-high power quality and harmonic mitigation. Its unique Three-lysed (three-split) secondary winding design provides three isolated and phase-shifted outputs, making it the core component for advanced 18-pulse or higher rectifier systems. By drastically reducing input current harmonics to levels far beyond standard 6 or 12-pulse systems, it ensures compliance with the strictest grid codes and provides a clean, stable, and reliable DC power source for the most demanding industrial applications.

Key Technical Features

  • Advanced Three-lysed Winding Design:Features three identical and isolated secondary windings, configured to create the necessary phase displacement (e.g., 0°, +20°, -20°). This is the foundation for superior 18-pulse rectification and minimal harmonic distortion.

  • Exceptional Harmonic Mitigation:Effectively reduces input current total harmonic distortion (THDi) to typically less than 5%, eliminating the need for large external harmonic filters and protecting sensitive equipment upstream.

  • Robust Oil-Immersed Construction:The oil-insulated and cooled design ensures excellent thermal management, high dielectric strength, and reliable operation in demanding environments, even under continuous heavy loads.

  • High Efficiency and Reduced Losses:Engineered with low-loss core materials and precision-wound conductors to maximize efficiency, lower operational costs, and reduce the total cost of ownership.

  • Enhanced System Reliability:Built to withstand the thermal and mechanical stresses associated with non-linear rectifier loads, ensuring long-term stability and minimizing downtime in critical processes.

Technical Parameters Table of ZSF Series 10kV Oil-immersed Three-split Rectifier Transformer

Product Model

Rated Capacity (kVA)

Voltage Combination and Tap Range

Connection Group

Short-Circuit Impedance (%)

Weight (kg)

Gauge (mm)

Outline Reference Dimensions (Length * Width * Height mm)

High Voltage (kV)

High Voltage Tap Range (%)

Low Voltage (kV)

Core Weight

Oil Weight

Total Weight

ZSF-600

600

6

6.3

10

10.5

11

±5%

±2×2.5%


(0.10~3.3) ×3


Dy11y11y11

Dd0d0d0

4.5

1187

515

2490

550

2025 * 700 * 1780

ZSF-900

900

2090

783

3515

820

2280 * 1260 * 1840

ZSF-1200

1200

2200

1150

4470

820

2000 * 1300 * 1840

ZSF-1500

1500

2723

1206

4790

820

2340 * 1300 * 1990

ZSF-2700

2700

3850

1530

7770

1070

2490 * 2365 * 2150

ZSF-3300

3300

7.0

4035

1650

7975

1070

2550 * 2450 * 2155

ZSF-3600

3600

5070

2280

9700

1070

2640 * 2800 * 2405

ZSF-4200

4200

5545

2540

9200

1070

2690 * 2910 * 2435

ZSF-4800

4800

5900

3100

12900

1070

2700 * 3150 * 2440

ZSF-6000

6000

8.0

7000

3270

14300

1475

2955 * 3220 * 2440

ZSF-7200

7200

7300

3370

15300

1475

2955 * 3220 * 2540

ZSF-8100

8100

7700

3800

19300

1475

2960 * 3240 * 2580

ZSF-9000

9000

8650

3800

20800

1475

2980 * 3540 * 2590

ZSF-9900

9900

9500

3980

23200

1475

3020 * 3925 * 2760

Typical Application Scenarios

  • High-Precision Industrial Drives: Powering large variable frequency drives (VFDs) in industries like mining, metals, and plastics, where ultra-low harmonics are crucial to prevent motor heating and controller malfunctions.

  • Critical Process Power Supplies: Serving as the power source for sensitive applications in petrochemical plants and semiconductor manufacturing, where any power quality issue can lead to massive production losses.

  • Data Center High-Efficiency Power Systems: Integrating into modern data center power infrastructure to ensure high-efficiency AC/DC conversion while meeting strict harmonic standards.

  • Test Facilities and R&D Labs: Providing exceptionally clean DC power for testing high-power equipment and for use in research and development settings that require pristine power quality.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.