• Rectifier Transformer (distribution transformer)
Rectifier Transformer (distribution transformer)
discuss personally
Model
SR11-4000/10
Basic info
Brand Vziman
Model NO. Rectifier Transformer (distribution transformer)
Rated capacity 4000KVA
Voltage grade 10KV
Series Rectifier Transformer
Product Detail

Product overview:

  •  A rectifier transformer is a transformer that converts the power supply of the grid into the power supply required by the rectifier equipment.

  •  Rectifier transformers (intermediate frequency furnace transformers) are widely used in.

  • Chemical industry (most used industry) electrolysis of non-ferrous metal compounds to produce aluminum, magnesium, copper and other metals; Electrolytic salt to make chlor-alkali. Electrolysis of water to produce hydrogen and oxygen.

  • Dc power supply for traction is used for DC power grid of mine or urban electric locomotive.

  • Dc power supply for transmission.

  •  Mainly used to supply power to DC motors in electric transmission, such as armature and excitation of rolling mill.

  • Other applications, including DC power supply for electroplating or electroprocessing, DC power supply for excitation, DC power supply for charging and electrostatic dust removal, etc.

  •  High reliability of operation verification in more than 50 countries and regions around the world.

  • Products are mainly exported to Iran, Kazakhstan, Uzbekistan and other countries and regions.

  •  Implementation standard: IEC 60076 series.

Leading technology:

  •  Large capacity, low loss, low noise (< 65dB) more energy saving.

  •  Excellent performance index, actual measurement is better than GB and IEC standards.

  • The product has strong over-load capacity and over-voltage capacity, and can run safely for a long time under rated load.

  • Strong impact resistance and short circuit resistance.

  • With microcomputer protection device (measurement, control, protection, communication, etc.).

The shell:

  • Mitsubishi laser cutting machine and CNC punching, reducing, folding and other equipment to ensure the accuracy of processing.

  • ABB robot automatic welding, laser detection, to avoid leakage, qualified rate of 99.99998%.

  • Electrostatic spray treatment, 30 years of paint (coating corrosion resistance within 100h, hardness ≥0.4).

  • Use heat dissipation tubing (double row and three row tubing adopt insert mode) to achieve good heat dissipation effect.

  • Fully sealed structure, maintenance-free and maintenance-free, normal operation life of more than 30 years.

The iron core:

  • The core material is high quality cold rolled grain oriented silicon steel sheet with mineral oxide insulation (from  Baowu Steel Group, China).

  • Minimize loss level, no-load current and noise by controlling the cutting and stacking process of silicon steel sheet.

  • The iron core is specially reinforced to ensure the transformer structure is firm during normal operation and transportation.

winding:

  • Low voltage winding is made of high quality copper foil, excellent insulation resistance.

  • The high voltage windings are usually made of insulated copper wire, using the patented technology of Hengfengyou Electric.

  • Very good resistance to radial stress caused by short circuit.

High quality material:

  • Baowu Steel Group production of silicon steel sheet.

  • China produces high quality anaerobic copper.

  • CNPC (Kunlun Petroleum) High quality transformer oil (25#).

Ordering instructions:

  • Main parameters of transformer (voltage, capacity, loss and other main parameters).

  • Transformer operating environment (altitude, temperature, humidity, location, etc.).

  • Other customization requirements.

  •  Normal delivery period is 30 days.

  • Worldwide fast delivery.

What is a Rectifier Transformer?

Functional Aspects:

  • A rectifier transformer is a special type of transformer, mainly used to convert alternating current (AC) voltage into a voltage suitable for the input of a rectifier. The function of a rectifier is to convert alternating current into direct current (DC), and the rectifier transformer provides the appropriate alternating current input voltage for the rectifier to ensure that the rectifier can perform the rectification operation effectively.

  • For example, in the industrial electroplating process, a stable direct current power supply is required for electroplating operations. The rectifier transformer first converts the alternating current from the power grid (such as 380V AC) into an alternating current voltage suitable for the electroplating rectifier (such as an alternating current voltage of several tens of volts), and then the rectifier converts this alternating current voltage into a direct current voltage for electroplating.

Structural Characteristics:

  • Its structure is similar to that of an ordinary transformer, also having an iron core and windings. However, the winding design of the rectifier transformer may be more complex because the direct current output characteristics after rectification need to be taken into account.

  • For example, in order to reduce the harmonic components in the direct current after rectification, the windings of the rectifier transformer may adopt special connection methods, such as extended delta connection or zigzag connection. These connection methods help to improve the electrical performance of the transformer, making the output alternating current voltage more suitable for rectification, thus obtaining a better-quality direct current output.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!