• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


11kV SF6 High Voltage Ring Main Unit Switchgear

  • 11kV SF6 High Voltage Ring Main Unit Switchgear

Key attributes

Brand ROCKWILL
Model NO. 11kV SF6 High Voltage Ring Main Unit Switchgear
Rated voltage 11kV
Rated frequency 50/60Hz
Series XGN

Product descriptions from the supplier

Description
Description

The ring main unit is based on SF6 load switch as the main switch, and the whole cabinet is suitable for distribution automation and compact and scalable metal-enclosed switchgear. It has the characteristics of simple structure, flexible operation, reliable interlocking and convenient installation. It can provide satisfactory technical solutions for different applications and users.

Feature

  • 11kV-class SF₆ high-efficiency insulation: Uses SF₆ gas as the insulating medium, with insulation strength precisely adapted to the 11kV high-voltage level and excellent arc-extinguishing performance. It can stably block current leakage in high-voltage environments, significantly reducing the risks of faults such as short circuits and flashovers, and ensuring the reliable operation of medium and high-voltage power grids.

  • Compact high-voltage adaptive design: Features a small and compact structure with a small footprint, making it particularly suitable for space-constrained 11kV high-voltage distribution scenarios such as urban distribution stations and industrial parks. It simplifies installation layouts while improving site utilization.

  • Multiple safety protection mechanisms: Equipped with complete mechanical and electrical interlocking devices to strictly prevent misoperations and incorrect switching; built-in SF₆ gas leakage monitoring system provides real-time warnings of leakage risks. It complies with international high-voltage equipment safety standards, ensuring safe operation and maintenance.

  • Low-maintenance and long-life characteristics: The fully sealed gas chamber design effectively isolates dust, moisture, and corrosive substances, reducing erosion of internal components by the external environment. It enables long-term maintenance-free operation with a service life of over 20 years, significantly lowering the whole-life-cycle cost.

  • Flexible power distribution compatibility: Supports multiple wiring methods such as ring network and radial types, and can be quickly connected with 11kV-class transformers, cables, and other equipment. It adapts to the topological requirements of different medium and high-voltage distribution networks, meeting diverse power supply scenarios including urban power grids and large industrial plants.

  • Balance of environmental protection and economy: SF₆ gas is recyclable and reusable, reducing resource waste; the equipment has low operating energy consumption, and long-term usage costs are controllable, balancing environmental protection requirements and project economic benefits.

Parameter

Product name

11kV 12kV indoor type gas insulated ring main unit switchgear

Application

Factory, School, Hotel, Hospital, Building

Function

Power Distribution Equipment

Ambient temperature

Maximum temperature: +40℃; Minimum temperature: -35℃

Altitude

Maximum installation height: 2500m

Relative humidity

The monthly average humidity is 95%; the daily average humidity is 90%.

Rated voltage

Between 3kv and 12kv

Rated current

630A/125A/1250A

Rated pressure of SF6 gas (gauge pressure)

0.045MPa

Maximum rated current of fuse

125kV

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.