• 250kVA-2500 kVA Compact substation(Prefabricated Substation)
  • 250kVA-2500 kVA Compact substation(Prefabricated Substation)
250kVA-2500 kVA Compact substation(Prefabricated Substation)
discuss personally
Model
YBM-800
YBM-630
YBM-250
YBM-1250
Basic info
Brand Vziman
Model NO. 1250 kVA Compact substation
Rated voltage 35kV
Capacity 800kVA
Series Compact Substation
Product Detail

Product overview:

  • 250- 2500kVA Compact substation can replace the traditional indoor substation, can meet the user's electric energy measurement, reactive power compensation, high and low voltage.

  • schemes and other configuration requirements, representing the development direction of small and medium-sized substations.

  •  Rated AC frequency 50Hz/60HZ, maximum operating voltage to 35KV, maximum operating current to 5000A.

  • This product is suitable for industrial and mining enterprises, wharfs, public places, high-rise buildings and residential areas.

  • Products are mainly exported to Asia, Africa and other regions, providing OEM/ODM services.

  • Standard: IEC60067 GB 17467-2010, etc.

Product advantages:
Leading technology:

  • Fully enclosed and insulated structure, safe and reliable operation.

  • Easy to operate, maintenance-free, low equipment cost.

The shell:

  • The casing has the characteristics of firm, heat insulation and ventilation, stable performance (anti-corrosion, dustproof, waterproof) and beautiful appearance.

  • Various choice of shell materials, such as steel plate, composite plate, stainless steel plate, cement plate and other protection grade (IP67) .

Functional units:

  • Divided into high voltage room, low voltage room, transformer room three independent areas.

  • XGN15, HXGN17 or SF6 switchgear is selected for high pressure chamber.

  • The low-voltage side adopts panel or cabinet mounted structure to form the power supply scheme required by users, which can meet the power distribution, lighting distribution,

    reactive power compensation, energy metering and other functions. The main switch generally uses universal circuit breaker, but also can choose intelligent circuit breaker, flexible installation, easy operation.

  • The transformer can be fully sealed oil-immersed transformer or dry transformer.

Busbar system:

  • Three-phase four-wire system or three-phase five-wire system.

  •  High quality three phase tinned bus copper bar, high mechanical strength, good heat dissipation..

Product parameters:

Conditions of use:

  •  The ambient air temperature shall not exceed a maximum of 45 ° C and a minimum of -45 ° C.

  •  The altitude is not more than 1000m, and can reach 4000m if special custom transformers and low-voltage components are used.

  •  The vertical inclination is not more than 5°, and there is no violent vibration and no impact.

  •  Air humidity not greater than 90% (+25℃).

  •  No conductive dust, no explosion hazard, no corrosive metal and electrical components in the gas place.

  • Outdoor wind speed should not exceed 35m/s.

  •  The above normal operating environment conditions, customers can be customized with WONE you Electric to solve.

Ordering instructions:

The customer shall provide the following information:

  • Main loop scheme diagram and secondary loop system diagram.

  • Electrical schematic diagram of auxiliary circuit and wiring terminal layout.

  • Equipment layout drawing, combination drawing, floor plan drawing.

  • Model, specification and quantity of main electrical components of the equipment.

  • Incoming and outgoing line method and cable specifications.

  • Equipment shell material and color.

  • Other special requirements can be negotiated with the manufacturer.

  • Welcome customers to visit the factory, provide OEM/ODM protection level.

Know your supplier
Vziman
Zhejiang Vziman Electric Group Co., Ltd. is a high-tech enterprise specializing in R&D, manufacturing, and service of power electrical equipment. Committed to innovation, quality, and customer satisfaction, it supplies smart solutions for global power sectors, covering grid construction, new energy, and industrial distribution. Core Business • Switchgear (GIS, circuit breakers, Recloser, Load break switch) • Distribution equipment (transformers, RMU, smart terminals) • Power automation systems • Engineering services (installation, maintenance, consulting) Technical Strength • Provincial R&D center, multiple patents • Modern production, ISO/GB/IEC/CE/UL certified • High capacity, large-scale delivery support Market & Vision Serves State Grid, Southern Grid, and global projects (Asia, Africa, Europe, etc.). Aims to lead in smart grids and new energy, promoting sustainable energy development.
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150000000
Professional Experience
3 years
Workplace
10000m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!