Key attributes

Brand Wone Store
Model NO. Busbar support porcelain insulator
Rated voltage 126kV
Rated frequency 50/60Hz
Series ZCW

Product descriptions from the supplier

Description

Product Description

Busbar support porcelain insulators are essential components in electrical power systems, designed to provide both mechanical support and electrical insulation for busbars—conductive bars that distribute electricity within switchgear, substations, and industrial equipment. Crafted from high-quality porcelain, these insulators prevent current leakage between busbars and grounded structures, ensuring safe and efficient power distribution even in high-voltage environments.

Main Feature

  • Dual Functionality: Combines robust mechanical support to hold busbars securely in place with reliable electrical insulation, preventing short circuits and ensuring system safety.

  • High Insulation Strength: Made from dense porcelain material with excellent dielectric properties, capable of withstanding high voltage levels without breakdown.

  • Mechanical Durability: Resistant to mechanical stress, vibration, and thermal expansion, maintaining stability in demanding industrial and substation settings.

  • Weather and Corrosion Resistance: Unaffected by moisture, dust, and chemical exposure, making them suitable for both indoor and outdoor applications.

  • Compliance with Standards: Manufactured to meet industry specifications, ensuring compatibility with various busbar systems and power distribution setups.

Main Parameters

Model

Rated voltage

The damage load is not small

Creepage distance

Main Dimensions (mm)

weight



curved

torsion


Overall height

Maximum umbrella diameter

Upper mounting holes

lower mounting holes



kV

kN

kN.m

mm

H

D

D1-n-d1

D2-n-d2

kg

ZCW1-126/N2-3

126


2

3150

1200

215

127-4-M16

160-4-Φ18

57

ZCW1.1-126/N2-3

126


2

3150

1200

215

160-4-Φ18

127-4-M16

57

ZCW1.2-126/N4-3

126


4

3150

1150

220

180-4-Φ13

180-4-Φ13

47

ZCW1.3-126/N4-3

126


4

3150

1150

215

160-4-Φ13

160-4-Φ13

49

ZCW1.4-126/N4-3

126

2.5

4

3150

1200

235

127-4-M16

225-4-Φ18

70

ZCW1.5-126/N4-3

126

2.5

4

3150

1200

235

225-4-Φ18

127-4-M16

70

ZSW1-126/8-3

126

8

8

3150

1150

240

140-4-M12

225-4-Φ18

85

ZSW1.1-126/8-3

126

8

8

3150

1150

255

225-4-Φ18

254-8-Φ18

101

ZSXW1-126/8-3

126

8

8

3150

1150

240

140-4-M12

225-4-Φ18

85

ZSXW1.1-126/8-3

126

8

8

3150

1150

255

225-4-Φ18

254-8-Φ18


ZSW1.2-126/8-3

126

8

6

3150

1170

240

140-4-M12

225-4-Φ18

86

ZSW1-126/10-3

126

10

7

3400

1200

260

127-4-M16

286-6-Φ18

87

ZSW1-126/12.5-3

126

12.5

10

3400

1200

265

225-4-Φ18

250-4-Φ18

114

ZSW1.1-126/12.5-3

126

12.5

10

3250

1150

265

225-4-Φ18

254-8-Φ18

111

ZSW1-126/16-3

126

16

10

3200

1150

265

225-4-Φ18

250-8-Φ18

111

ZSW1.1-126/16-3

126

16

10

3200

1150

265

254-8-Φ18

254-8-Φ18

112

ZSW1-126/20-3

126

20

10

3150

1200

275

275-8-Φ18

300-8-Φ18

137

ZSW1.1-126/20-3

126

20

10

3150

1200

275

275-8-Φ18

280-8-Φ18

137

ZSW1-126/25-3

126

25

10

3150

1150

290

254-8-Φ18

275-8-Φ18

137

ZSW1-126/25-3

126

25

10

3150

1150

290

254-8-Φ18

275-8-Φ18

137

ZCW1.6-126/N4-4

126


4

3906

1150

260

180-4-Φ13

180-4-Φ13

79

ZSW1.8-126/8-4

126

8

6

3906

1200

280

225-4-Φ18

225-4-Φ18

100

ZSW1.9-126/8-4

126

8

4

3906

1200

280

140-4-M12

225-4-Φ18

99

ZSW1.4-126/10-4

126

10

10

4080

1200

295

225-4-Φ18

254-8-Φ18

116

ZSW1.3-126/12.5-4

126

12.5

6

3906

1200

280

225-4-Φ18

254-8-Φ18

108

ZSW1.2-126/16-4

126

16

10

3906

1200

306

225-4-Φ18

254-8-Φ18

121

ZSW1.2-126/20-4

126

20

10

4080

1200

305

254-8-Φ18

275-8-Φ18

136

ZSW1.1-126/25-4

126

25

10

3906

1200

336

254-8-Φ18

300-8-Φ18

165

ZSW1-126/40

126

40

10

3740

1200

340

275-8-Φ18

300-8-Φ18

181

ZSW1-145/6-3

145

6

4

3625

1400

240

127-4-M16

200-4-Φ18

81

ZSW1-145/8-3

145

8

6

3800

1400

250

140-4-M12

225-4-Φ18

107

ZSW1.1-145/8-3

145

8

6

3800

1400

250

127-4-M16

225-4-Φ18

109

ZSW1.3-145/8L-3

145

8

6

3800

1420

250

140-4-M12

140-4-M12

103

ZSW1.3-145/8-3

145

8

4

4100

1400

270

225-4-Φ18

254-8-Φ18

102

ZSW1-145/12.5-3

145

12.5

10

3800

1400

260

225-4-Φ18

250-4-Φ22

126

ZSW1-145/16-4

145

16

10

4850

1500

295

225-4-Φ18

254-8-Φ18

160

ZSW1.1-145/16-4

145

16

10

4850

1500

295

254-4-Φ18

275-8-Φ18

153

ZSW1-145/20-4

145

20

10

5150

1500

305

225-4-Φ18

275-8-Φ18

159

ZSW1.1-145/20-4

145

20

10

4500

1500

295

225-4-Φ18

270-4-Φ18

152

ZSW1-145/25-4

145

25

12

4800

1500

317

275-8-Φ18

300-8-Φ18

185

ZSW1-145/30-4

145

30

10

4500

1400

335

275-8-Φ18

300-8-Φ18

205

ZCW1-252/N2.5L-3

252


2.5

6300

2400

240

127-4-M16

127-4-M16

161

ZCW1.1-252/N4

252


4

5500

2300

205

180-4-Φ13

180-4-Φ13

95

ZCW1.2-252/N4-3

252


4

6300

2300

220

210-4-Φ18

210-4-Φ18

95

ZSW1-252/6-3

252

6

3

6300

2300

250

127-4-M16

225-4-Φ18

160

ZSW1.3-252/6-3

252

6

3.5

7300

2300

280

140-4-M12

254-8-Φ18

176

ZSW1.4-252/6-3

252

6

6

7400

2800

260

140-4-M12

250-4-Φ22

234

ZSW1.5-252/6-3

252

6

6

7400

2800

260

127-4-M16

270-4-Φ18

237

ZSXW1-252/8-3

252

8

8

6300

2300

265

140-4-M12

254-8-Φ18

197

ZSXW1.1-252/8-3

252

8

8

6300

2300

265

225-4-Φ18

254-8-Φ18

217

ZSW1.1-252/8-3

252

8

8

6300

2300

265

140-4-M12

250-8-Φ18

200

ZSW1.2-252/8-3

252

8

8

6300

2300

265

225-4-Φ18

250-8-Φ18

215

ZSW1-252/10-3

252

10

8

6300

2300

290

225-4-Φ18

254-8-Φ18

223

ZSXW1-252/12-3

252

12

10

6400

2300

290

225-4-Φ18

275-8-Φ18

250

ZSW1.1-252/12.5-3

252

12.5

10

6700

2500

300

225-4-Φ14

300-8-Φ18

239

ZSW1-252/20-3

252

20

10

6300

2300

335

254-8-Φ18

300-8-Φ18

322

ZSW1.6-252/6-4

252

6

4

7812

2400

280

140-4-M12

254-8-Φ18

208

ZSW1.4-252/8-4

252

8

8

7812

2400

315

140-4-M12

300-8-Φ18

264

ZSW1.2-252/10-4

252

10

10

7812

2400

300

225-4-Φ18

254-8-Φ18

250

ZSW1.2-252/12.5

252

12.5

8

7812

2400

335

225-4-Φ18

325-8-Φ18

306

ZSW1.1-252/16-4

252

10

10

7812

2400

336

225-4-Φ18

300-8-Φ18

288

ZSW1.1-252/20-4

252

20

10

7812

2400

340

254-8-Φ18

300-8-Φ18

318

ZSW1.2-252/20-4

252

20

10

8775

2800

350

254-8-Φ18

325-8-Φ18

397

ZSW1-252/25-4

252

25

10

8200

2800

355

275-8-Φ18

325-8-Φ18

436

ZSW1-363/6

363

6

3

9700

3500

280

140-4-M12

254-8-Φ18

295

ZSW1.1-363/6-4*

363

6

3

11280

3500

300

140-4-M12

254-8-Φ18

346/341

ZSW1-363/8-3

363

8

10

9075

3320

310

140-4-M12

270-6-Φ18

332

ZSW1.1-363/8-3

363

8

4

9080

3500

290

190-4-Φ18

300-8-Φ18

322

ZSW1-363/10-3

363

10

6

9075

3460

300

225-4-Φ18

300-8-Φ18

368

ZCW1-363/N4-3

363

12

6

9080

3500

315

127-4-M16

325-8-Φ18

378

ZCW1-363/N4-3

363


4

9080

3500

235

127-8-M10

127-8-M10

233

ZCW1.1-550/N4-3

550


4

13750

4400

225

210-4-Φ18

210-4-Φ18

250

ZCW1.2-550/N4-3

550


4

13750

4700

290

210-4-Φ18

210-4-Φ18

378

ZSW1-550/8-3

550

8

6.4

13750

4000

300

127-4-M16

300-8-Φ18

435

ZSW1.1-550/8-3

550

8

10

13750

4400

310

275-8-Φ18

300-8-Φ18

505

ZSW1.2-550/8-3*

550

8

8

13750

4400

310

225-4-Φ18

300-8-Φ18

499/493

ZSW1.3-550/8-3*

550

8

8

14200

4500

335

225-4-Φ18

325-8-Φ18

540/534

ZSW1-550/10-3*

550

10

10

13750

4000

336

225-4-Φ18

325-8-Φ18

540/535

ZSW1.1-550/10-3*

550

10

10

13750

4400

342

225-4-Φ18

325-8-Φ18

562/556

ZSW1-550/12-3

550

12

10

13750

4400

342

275-8-Φ18

325-8-Φ18

568

ZSW1.1-550/12-3

550

12

10

13750

4400

342

127-4-M16

325-8-Φ18

559

ZSW1-550/12.5-3*

550

12.5

10

13750

4400

342

225-4-Φ18

325-8-Φ18

562/556

ZSW1.1-550/12.5-3

550

12.5

10

13750

4400

342

275-8-Φ18

300-8-Φ18

568

ZSW1-550/16-3*

550

16

10

13750

4400

355

225-4-Φ18

325-8-Φ18

622/616

ZSW1-550/16-3*

550

16

10

13750

4400

355

225-4-Φ18

325-8-Φ18

622/616

ZSW1-550/16-3*

550

16

10

13750

4400

355

225-4-Φ18

325-8-Φ18

622/616

ZSW1-550/16-3*

550

16

10

13750

4400

355

225-4-Φ18

325-8-Φ18

622/616

ZSW1.1-550/12.5-3*

550

12.5

10

13750

4400

342

275-8-Φ18

300-8-Φ18

568

ZSW1-550/16-3*

550

16

10

13750

4400

355

225-4-Φ18

325-8-Φ18

622/616

ZSW1.1-550/16-3

550

16

10

13750

4400

355

127-4-M16

325-8-Φ18

619

ZSW1.2-550/16-3*

550

16

10

13750

4400

355

254-4-Φ18

356-8-Φ18

624/618

ZSW1.3-550/16-3

550

16

10

13750

4400

355

275-8-Φ18

325-8-Φ18

629

ZSW1.4-550/16-3*

550

16

10

13750

4700

350

254-4-Φ18

356-8-Φ18

662/656

ZSW1.5-550/16-3

550

16

10

13750

4400

355

275-8-Φ18

356-8-Φ18

628

ZSW1-550/20-3*

550

20

10

13750

4400

350

225-4-Φ18

325-8-Φ18

655.4/649.9

ZSW1.4-550/8-4*

550

8

10

17050

5000

335

225-4-Φ18

325-8-Φ18

622/617

ZSW1.5-550/8-4

550

8

6

17050

4700

349

275-8-Φ18

300-8-Φ18

620

ZSW1.3-550/12-4

550

12

10

17050

4700

364

127-4-M16

325-8-Φ18

668

ZSW1.4-550/12-4*

550

12

10

17050

5100

366

254-4-Φ18

325-8-Φ18

737/731

ZSW1-550/12.5-4

550

12.5

10

17050

4700

364

275-8-Φ18

325-8-Φ18

689

ZSW1-550/12.5-4

550

12.5

10

17050

4700

364

275-8-Φ18

325-8-Φ18

689

ZSW1-550/14-4*

550

14

12

17050

5100

384

254-4-Φ18

325-8-Φ18

830/824

ZSW1.5-550/16-4*

550

16

12

17050

5100

400

254-4-Φ18

356-8-Φ18


ZSW1.6-550/16-4

550

16

12

17050

5100

399

254-4-Φ18

325-8-Φ18

863/857

ZSW1.7-550/16-4

550

16

10

17050

4700

387

275-8-Φ18

325-8-Φ18

759

ZSW1.1-550/20-4*

550

20

15

17050

5100

419

254-8-Φ18

356-8-Φ18

966/960

ZSW1.1-800/16-3

800

16

10

22400

6800

415

127-4-M16

375-8-Φ18

1296

ZCW1-800/N6-3

800


6

22400

6800

330

254-4-Φ18

254-4-Φ18

877

ZSW1.4-800/16-3

800

16

10

21000

7200

405

275-8-Φ18

375-8-Φ18

1312

ZSW1-800/12.5-3*

800

12.5

10

20000

6600

355

254-4-Φ18

356-8-Φ18

963/955

ZSW1-1100/12.5-3*

1100

12.5

20

30250

11000

435

310-10-Φ18

410-12-Φ22

2450

ZSW1-1100/16-3*

1100

16

20

27500

8800

425

310-10-Φ18

410-12-Φ22

1806/1789

ZSW1.1-1100/16-3

1100

16

10

27500

8400

342

127-4-M16

400-8-Φ22

1777

ZSW1.2-1100/16-3*

1100

16

10

30250

10000

460

300-8-Φ18

460-12-Φ22

2627/2536

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.