126kV/800kV supporting parts

  • 126kV/800kV supporting parts

Key attributes

Brand Switchgear parts
Model NO. 126kV/800kV supporting parts
Rated voltage 126/800kV
Series RN

Product descriptions from the supplier

Description

126kV and 800kV supporting components are mainly used to support and insulate electrical equipment in power systems, ensuring the safety and stability of power transmission. Here are some common parts of this type:
126kV supporting parts:
Outdoor pole shaped ceramic insulator: mainly used in 126kV outdoor electrical equipment to provide support and insulation. Its nominal height is generally around 1200mm, and the creepage distance is over 2000mm depending on different models. The rated bending failure load can reach 6kN, etc.
GIS supports insulators: In 126kV GIS (gas insulated metal enclosed switchgear), supporting insulators are used to support and fix conductors, ensuring insulation performance between conductors and casings. Their materials are generally ceramic or epoxy resin.
Cable terminal support components: such as 3M's TG123-II dry-type pluggable cable terminal, suitable for cable systems with voltage levels of 126kV and below. The support components are used to fix and support cable terminals, ensuring stable connection between cable terminals and GIS switchgear or transformers. They use prefabricated stress cones and insulation fillers, and have good insulation performance and anti creepage performance.
800kV supporting parts:
Outdoor Rod shaped Pillar Porcelain Insulators: 800kV outdoor rod shaped pillar porcelain insulators produced by Xi'an Xidian High Voltage Porcelain Co., Ltd. are used in 800kV ultra-high voltage transmission lines and substations as insulation and support components for conductive parts, with high mechanical strength and insulation performance.
High voltage pulse source supporting insulator: In an 800kV high voltage pulse source, supporting insulators are used to support and insulate internal components such as the movement supporting insulator in the Marx main chamber of the 800kV high voltage pulse source. The main material is 304 stainless steel, which has good insulation performance and mechanical strength to ensure the normal operation of the high voltage pulse source.
Cross arm end card: such as the 800kV cross arm end card NHDK140 of Hanzhong Qunfeng, used for tension string of 800kV AC and DC transmission lines, used in conjunction with closed cards to replace the first insulator of the cross arm end. The card material is TC4 titanium alloy, with a working load of 140KN and a static test load of 350KN, and has the characteristics of high strength and light weight.

Note: Customization with drawings is available

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.