12kV 13.2kV 13.8kV 14.5kV Environment-friendly Gas-insulated Metal-enclosed Switchgear/switchboard panel

  • 12kV 13.2kV 13.8kV 14.5kV Environment-friendly Gas-insulated Metal-enclosed Switchgear/switchboard panel
  • 12kV 13.2kV 13.8kV 14.5kV Environment-friendly Gas-insulated Metal-enclosed Switchgear/switchboard panel

Key attributes

Brand ROCKWILL
Model NO. 12kV 13.2kV 13.8kV 14.5kV Environment-friendly Gas-insulated Metal-enclosed Switchgear/switchboard panel
Rated voltage 12kV
Rated frequency 50/60Hz
Series NGH

Product descriptions from the supplier

Description
Description

12kV 13.2kV 13.8kV 14.5kV Environment-friendly Gas-insulated Metal-enclosed Switchgear/switchboard panel Application: used in power stations, medium & small-sized power plant, substation, high-rise building, industrial and mining enterprises, subway, electrical railway and other power distribution systems, for the control, receiving, distribution, protection and monitoring of power supply systems and electric energy.

The 12kV Environment-friendly Gas-insulated Metal-enclosed Switchgear is a cutting-edge power distribution solution designed for modern green grids. It replaces traditional SF₆ with eco-friendly insulating gas, combining high performance with low environmental impact. Suitable for urban power networks, renewable energy plants, and industrial facilities, it ensures safe, efficient power distribution in a compact, metal-enclosed structure, aligning with global sustainability goals.

Key Features

  • Eco-friendly Insulation:Adopts non-toxic, low-GWP (Global Warming Potential) gas instead of SF₆, eliminating greenhouse gas emissions and meeting strict environmental regulations (e.g., EU F-gas Directive).

  • High Safety & Reliability:All-metal enclosed structure with advanced sealing technology prevents gas leakage and resists external interference (dust, moisture, electromagnetic fields), ensuring stable operation in harsh conditions.

  • Compact Design:Space-saving structure reduces installation footprint by up to 30% compared to conventional switchgear, ideal for urban areas or sites with limited space.

  • Low Maintenance:Hermetic gas chamber and durable components minimize wear, extending maintenance intervals and reducing operational costs over the lifecycle.

  • Flexible Compatibility:Supports various wiring modes (ring network, radial) and integrates with smart grid systems, enabling remote monitoring and adaptive protection for intelligent power management.

  • Compliance with Standards:Certified by international norms (IEC, ANSI) for safety and performance, ensuring seamless integration into global power distribution networks.

Parameters 

The voltage classes of some of these eco-friendly switchgears include 6kV, 6.3kV, 6.6kV, 6.9kV, 7.2kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 13.2kV, 13.8kV, 14.5kV, 14.4kV, 15kV, 15.5kV, 15.6kV, 17.5kV, 20kV, 21.9kV, 22kV, 24kV, 30kV, 33kV, 33.5kV, 34.5kV, 35kV, 36kV, 38kV, 38.5kV, 40.5kV, 44kV, 45kV, 46kV, 66kV and 69kV. and customization is available.

  • Standards: IEC 62271-200, IEC 62271-1, IEC 62271-100, IEC 62271-102

  • Parameters: Rated voltage: 3.6-12kV.

  • Rated current: 630-3150A.

  • Rated short-circuit breaking current: 40kA.

 

FAQ
Q: Is pure air more reliable than dry air for environmentally friendly cabinet insulation?
A:
Pure air is more reliable in insulation stability but is more costly. Pure air undergoes multi-stage purification to remove dust, oil mist, and impurities, with a lower dew point (≤ -50℃ or lower). It has better anti-partial discharge performance in high-voltage gradients, suitable for 24kV and above high-reliability scenarios. Dry air only undergoes dehydration treatment, with higher impurity content, suitable for 12kV conventional distribution scenarios. Both meet insulation requirements for their respective application scenarios.
Q: What voltage levels are environmentally friendly cabinets suitable for?
A:
Environmentally friendly cabinets are mainly suitable for medium-voltage systems, with common voltage levels including 12kV, 24kV, and 35kV. 12kV cabinets are the most widely used in urban distribution networks, residential communities, and industrial parks. 24kV and 35kV cabinets are suitable for large industrial plants and regional power distribution systems. Some manufacturers also develop low-voltage eco-friendly cabinets, but medium-voltage applications are the main focus.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.