• 252kV outdoor self-energy power high voltage SF6 circuit breaker
252kV outdoor self-energy power high voltage SF6 circuit breaker
discuss personally
Model
LW58-252(W)/T5000-63
LW58-252(W)/T4000-50
Basic info
Brand ROCKWILL
Model NO. 252kV outdoor self-energy power high voltage SF6 circuit breaker
Rated voltage 252kV
Rated normal current 5000A
Rated frequency 50/60Hz
Rated short circuit breaking current 63kA
Series LW58-252
Product Detail

Product introduction:

The LW58-252(W) outdoor self-energy high-voltage SF₆ circuit breaker is designed for 252kV, 50Hz AC power systems, serving as a critical control and protection device for power grid interconnections. Utilizing SF₆ gas for arc quenching and insulation, it features a self-energy power arc extinguishing double-action interrupter structure paired with a new-type spring operating mechanism. Renowned for its robust switching capability, low operating power, low noise, and high reliability, its technical indicators align with advanced domestic and international counterparts.

This three-phase SF₆ circuit breaker upgrades from single-pole, single-mechanism operation to a three-phase mechanical linkage system driven by a single mechanism. This design reduces mechanical complexity, enhances three-phase linkage reliability, and eliminates the risk of single-phase misoperation.

Main characteristic:

  • Self-Energy Arc Extinguishing Technology: The double-action structure ensures stable breaking capacity under diverse loads.

  • High Operational Efficiency: Requires minimal operating power, with a mechanical life cycle of up to 10,000 cycles for prolonged reliability.

  • Superior Contact Design: Copper-tungsten arc contacts use integral sintering, withstanding high temperatures, minimal arc erosion, and over 20 full breaking operations.

Reliable Sealing & Insulation:

  • Annual SF₆ gas leakage rate < 0.5% via precision sealing technology.

  • Stringent dehumidification processes ensure SF₆ moisture content far below industry standards.

  • High insulation level with creepage distance > 31mm/kV.

Advanced Materials:

  • Arc extinguishing chamber valve plates use lightweight zinc-base alloy for stable gas dynamics and breaking performance.

  • Imported PTFE-composite nozzles offer excellent ablation resistance and consistent arc quenching.

  • Premium Components: Secondary circuit electrical units and SF₆ density relays are high-quality impact-resistant or joint-venture products.

  • Pure Spring Operating Mechanism: Forged from high-strength alloy steel, key components resist wear, ensuring low failure rates during frequent operations.

Main technical parameters:

1732504456227.png

Instructions on placing orders  : 

  • Model and format of the circuit breaker;

  • Rated electrical parameters (voltage, current, breaking current, etc);

  • Working conditions for using (environment temperature, altitude, and environment pollution level);

  • Rated control circuit electrical parameters (Rated voltage of energy-store moter and Rated voltage of opening, closing coil);

  • Names and quantities of spare items needed, parts and special equipment and tools (to be otherwise ordered);

  • The wire connecting direction of the primary upper terminal.

What are the main types of tank circuit breakers?

SF6 Gas-Insulated Circuit Breaker:

  • SF6 Gas-Insulated Circuit Breaker: Uses sulfur hexafluoride (SF6) gas as the insulating and arc-quenching medium. SF6 gas has excellent insulating properties and arc-quenching capabilities, allowing it to meet the high voltage and high current breaking and insulation requirements in a small space. It is widely used in high-voltage and ultra-high-voltage power systems.

Oil-Immersed Circuit Breaker:

  • Oil-Immersed Circuit Breaker: Uses insulating oil as the insulating and arc-quenching medium. Insulating oil has good insulating properties and heat dissipation capabilities, effectively extinguishing arcs and cooling the contacts. However, due to the fire risk and environmental pollution associated with insulating oil, its application range has gradually decreased. Currently, it is mainly used in specific situations where fire prevention requirements are not stringent.


Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer.Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source.Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs).Process Layer: Features monitoring terminals for Potential Transformers (PTs) and
Oliver Watts
07/30/2025
Improvement and Application of the Test Device for Surge Arrester Online Monitor
Improvement and Application of the Test Device for Surge Arrester Online Monitor
1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Efficienc
Edwiin
07/30/2025
Design of Monitoring System for Surge Arrester in GIS Cubicle of 10kV Power Distribution System for High-Speed Railways
Design of Monitoring System for Surge Arrester in GIS Cubicle of 10kV Power Distribution System for High-Speed Railways
1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo ensure
Dyson
07/30/2025
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a 50Hz-Designed Power Transformer Operate on 60Hz Grid?If a power transformer is designed and built for 50Hz, can it run on a 60Hz grid? If so, how do its key performance parameters change?Key Parameter ChangesShort-Circuit Impedance:For a given transformer (same voltage and capacity), short-circuit impedance is proportional to frequency. Thus, a 50Hz-designed unit operating at 60Hz sees a 20% increase—higher frequency intensifies alternating leakage field opposition to current.No-Load
Vziman
07/29/2025
What are the common faults of overhead cables?
What are the common faults of overhead cables?
Overhead cables, due to their exposure to external environments, are subject to various influences that can lead to different types of faults. Below are some common types of faults in overhead cables and their causes:1. Mechanical DamageCaused by external forces such as falling trees, vehicle collisions, or construction accidents.Prolonged vibrations or swinging can also cause material fatigue in cables.2. Weather-Related FaultsLightning Strikes: Direct hits or nearby lightning strikes can cause
Felix Spark
07/29/2025
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
A core challenge in online cable eccentricity measurement is the cable’s high - speed motion. This requires non - contact measurement equipment that can handle cable jitter. X - ray cable eccentricimeters, based on optical transmission imaging, measure multi - layer contour dimensions to calculate the geometric center of conductors relative to insulation eccentricity. However, they have drawbacks: slow measurement speed (only a few times per second), increased errors from cable jitter, and
Oliver Watts
07/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!