252kV Single-phase bowl insulator

  • 252kV Single-phase bowl insulator

Key attributes

Brand Switchgear parts
Model NO. 252kV Single-phase bowl insulator
Rated voltage 252kV
Series RN

Product descriptions from the supplier

Description

The single-phase bowl insulator (referred to as "single-phase bowl") used in 252kV GIS equipment is a key component of high-voltage gas insulated switchgear, and its design needs to take into account both insulation performance and mechanical strength. The following are comprehensive technical points and application analysis:
1、 Core design parameters
Voltage level
Suitable for 252kV system, power frequency withstand voltage 230kV (to ground/break), lightning impulse withstand voltage 550kV
Typical SF6 gas pressure is 0.4-0.6MPa, local discharge capacity ≤ 5pC
Structural optimization
Adopting a double-sided symmetrical curved design, the electric field strength is reduced by more than 25% compared to a unidirectional convex design, and the deformation is reduced by 30%
Aluminum free ring structure reduces SF6 gas consumption by 15% while avoiding local electric field distortion
2、 Performance verification and fault analysis
Experimental verification
Verify the design margin through insulation testing and water pressure failure testing (1.5 times rated pressure) at Kunming Ultra High Voltage Test Base
In the 252kV GIS fault statistics, discharge faults caused by foreign objects account for 29%, with the highest risk of breakdown occurring when metal shavings are arranged in sheet form in the low potential area
Foreign object influence
Metal shavings adhering to high potential areas do not cause breakdown, but the sheet-like arrangement in low potential areas can easily lead to discharge; The partial discharge of non-metallic foreign objects (such as sand particles) is significantly higher than that of other types
3、 Typical application scenarios
Urban power grid: 252kV GIS is widely used for busbar connection in 220kV substations, such as the Xinjiang Tianfu Energy Xuhui 220kV transmission and transformation project
Industrial power supply: equipped with 252kV/4000A-50kA combination electrical appliances (HGIS) to meet high current requirements

Note: Customization with drawings is available

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.