• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


5-10kW Wind&Solar Hybrid System

  • 5-10kW Wind&Solar Hybrid System
  • 5-10kW Wind&Solar Hybrid System

Key attributes

Brand Wone Store
Model NO. 5-10kW Wind&Solar Hybrid System
Rated Output Rating 5kW
Output Voltage AC 220V/230V
Series WPHB

Product descriptions from the supplier

Description

A wind-solar hybrid system effectively integrates wind and solar energy into a single power generation system. An off-grid wind-solar hybrid power system operates independently to provide electricity for specific areas or individual households. It mainly consists of a wind turbine, solar panels, a wind-solar hybrid charge controller and inverter, battery bank, and other accessories.

Within the renewable energy framework, solar and wind energy are two widely applied renewable resources. Compared to standalone photovoltaic or wind power generation, wind-solar hybrid generation significantly enhances the system's adaptability to weather variations, thereby improving its practical value. Utilizing renewable energy through wind-solar hybrid systems is a cost-effective and highly efficient approach for promoting energy infrastructure development in remote, off-grid, or electricity-deficient areas.

Introduction

10kW wind energy storage system, which combines wind turbine control, battery charge management and invert function in one system, can be used for both on-grid and off-grid systems.

Features

  • MPPT control for 10kW wind turbine

  • Both off-grid and on-grid feasible

  • Both grid and diesel engine can charge the battery

  • RS232/RS485/RJ45 monitoring connection modes optional

  • Can add inverter to be wind&solar hybrid system

Parameters

product number

WPHBS48-5-5K

WPHBS48-10-10K

WPHBT48-10-10K

Wind Turbine

Model

FD6-5000

FD6-5000

FD6-5000

Configuration

1S1P

1S2P

1S2P

Rated output Voltage

48V

48V

48V

Photovoltaic

Model

SP-580-V

SP-580-V

SP-580-V

Configuration

3S1P

3S2P

3S2P

Rated output Voltage

144V

144V

144V

Controller

Model

WWS50-48

WWS100-48

WWS100-48

Rated input Voltage

48V

48V

48V

Rated output Voltage

48V

48V

48V

Configuration

1S1P

1S1P

1S1P

Energy storage Battery

Model

W4850

W4850

W4850

Rated Voltage

48V

48V

48V

Rated capacity

4.8kWh

9.6kWh

9.6kWh

Configuration

1S1P

1S2P

1S2P

Inverter

Model

PW-5K

PW-5K

PX-10K

Rated input Voltage

48V

48V

48V

Rated

Power

5kW

5kW

10kW

Rated output Voltage

Single-phaseAC220V 50/60Hz

Single-phaseAC220V 50/60Hz

Three-phaseAC380V 50/60Hz

Configuration

1S1P

1S2P

1S1P

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Dedicated Vacuum Contactor Solution for Port Shore Power Systems
    I. Background and Challenges​Shore power systems have become core technical equipment for ports to reduce carbon emissions and noise pollution. However, these systems face two major challenges in the harsh operational environment of ports:​Severe Environmental Corrosion: High humidity and salt spray in port areas cause serious corrosion to metal components and enclosures of electrical equipment, significantly impacting electrical lifespan and operational reliability.​High Switching Requirements:
    09/13/2025
  • ABB Vacuum Contactor KC2 Power Supply System Technical Transformation Plan
    Issue Overview​The 10kV air compressor starting system of a company utilizes the ABB vacuum contactor KC2 as the control component for the operating circuit. The dedicated wide-voltage power supply module paired with this contactor presents the following issues:​Frequent failures: The power supply module fails to properly transition the voltage from 300V to 12V, resulting in fuse blowouts.​Poor heat dissipation: Enclosed installation of the module leads to insufficient heat dissipation, acceler
    09/13/2025
  • Solution for Medium-Voltage Motor Control and Protection Using Vacuum Contactor-Fuse (VCF) in a Coal Conveying System
    1.Project BackgroundA coal conveying system comprises 15 belt conveyors driven by medium-voltage motors. The system operates under complex conditions, with motors often subjected to heavy loads and frequent starts. To address these challenges and achieve effective control and reliable protection during motor startup, the project comprehensively adopts Vacuum Contactor-Fuse (VCF) combination devices for the 6kV medium-voltage motor power distribution. This solution details the technical features,
    09/13/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.