• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


550kV Aluminum free ring basin insulator

  • 550kV Aluminum free ring basin insulator

Key attributes

Brand Switchgear parts
Model NO. 550kV Aluminum free ring basin insulator
Rated voltage 550kV
Series RN

Product descriptions from the supplier

Description

The 550kV aluminum free ring pot insulator is a key insulation component in high-voltage GIS equipment, and its design achieves miniaturization and environmental protection through structural optimization and material innovation. The following is a comprehensive technical analysis:
Core design features
Geometry optimization
Adopting a contour design of "thick on both sides and thin in the middle", the maximum electric field strength along the concave surface is reduced by 25.4%, and the deformation is reduced by 29.9%
Optimize thickness variables (H ₁, H ₂, etc.) and contour variables (C ₁ ₂, C ₁ ∝, etc.) through genetic algorithm to balance electrical and mechanical performance
Advantages of aluminum free ring structure
Cancel traditional metal shielding rings to avoid local electric field distortion and simplify manufacturing processes
Reduce SF6 gas usage by 15% and epoxy composite material usage by 6.1%
2、 Application of dielectric gradient materials
3D printing+casting process
Using aluminum oxide/photosensitive resin 3D printing low dielectric constant body (ε=3.98-4.20), titanium dioxide/epoxy resin casting high dielectric constant region (ε=11.32-14.58)
The electric field distortion near the grounding flange has been significantly improved, and the flashover voltage has increased by 13.8%
Electric field regulation effect
After optimization, a high dielectric constant region is formed on one side of the convex surface near the outer flange of the insulator, greatly alleviating the phenomenon of electric field concentration
3、 Performance parameters and validation
Electrical performance
Power frequency withstand voltage 230kV, lightning impulse withstand voltage 550kV, local discharge capacity ≤ 5pC
When metal foreign objects are present, the flashover voltage can still be increased by 6.7%
Mechanical strength
The maximum deformation is reduced to 0.45mm, and the interface stress is below 70MPa
Verify reliability through hydraulic failure test (1.5 times rated pressure)
4、 Application and Environmental Benefits
Typical scenario
Suitable for 550kV GIS equipment, such as ultra-high voltage transmission projects or high-altitude environments
Can replace the traditional "R-arc" metal shielding structure and simplify the miniaturization transformation of GIS
Environmental Contribution
Reduce SF6 gas usage by 15%, in line with environmental trends
5、 Patent and tooling technology
Pressure resistant tooling design: adopting a transition tank body and conductive spring structure, supporting synchronous detection of multiple bowl insulators
Embedded optimization: The cylindrical conductive electrode is designed with arc-shaped protrusions to improve sealing and electric field uniformity

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.