ARD2F Motor Protection Controller

  • ARD2F Motor Protection Controller

Key attributes

Brand RW Energy
Model NO. ARD2F Motor Protection Controller
Rated frequency 50/60Hz
Series ARD2F

Product descriptions from the supplier

Description

General

ARD2F intelligent motor protector (hereinafter referred to as the protector) is suitable for low-voltage motor circuits with rated voltage up to 660V and integrates protection, measurement, control, communication, operation and maintenance.Its perfect protection function ensures the safe operation of the motor, with logic programmable function, can meet a variety of control methods.

Functional features

  • Protective function

  • Control function:A variety of control methods, programmable input and output

  • Measurement, monitoring:Three-phase voltage, current, active power, electric energy, leakage current, power factor, PTC/NTC

  • Operation and maintenance records

  • Communication

  • Human-computer interaction

Parameters

Technical parameters

Technical indicators

Protector auxiliary power supply

Support two power modules, AC 220V power module (AC85-265V/DC100-300V) default, AC 380V power module (AC/DC100-415V) optional

Rated working voltage of the motor

AC220V / 380V / 660V,50Hz / 60Hz

Rated operating current of the motor

1 (0.1A-5000A)

External current transformer

5 (0.1A-5000A)

1.6 (0.4A-1.6A)

6.3 (1.6A-6.3A)

25(6.3A-25A)

100(25A-100A)

250(63A-250A)

800(250A-800A)

Relay output contact capacity

Impedance load

AC250V、10A

Switching input

10 channels of passive dry contact (active DC110V, DC220V, AC220V input can be optional)

Communication

MODBUS RTU communication,PROFIBUS_DP communication

Environment

Working temperature

-10ºC~55ºC

Storage temperature

-25ºC~70ºC

Relative humidity

≤95﹪No condensation, no corrosive gas

Altitude

≤2000m

Pollution levels

Class 3

Protection grade

Main body IP20, split display module IP54 (installed on the cabinet panel)

Installation category

Level III

Dimensions

FAQ
Q: Does ARD2F support leakage protection and temperature monitoring?
A:

Support! ARD2F can be equipped with leakage current detection function and supports the connection of PTC/NTC temperature sensors for motor winding overheating protection, improving overall safety and intelligence level.

Q: How is the input/output interface configuration of ARD2F? Can it meet complex control logic?
A:

ARD2F provides 10 passive dry contact digital inputs (optional active DC110V/220V or AC220V inputs) and multiple programmable relay outputs. With its programmable logic function, it can flexibly implement various start stop, interlock, and alarm control logics.

Q: What communication protocols does ARD2F support? Does it support Profibus DP?
A:

Yes, ARD2F supports both Modbus RTU and Profibus DP industrial communication protocols, making it easy to integrate with PLC, DCS, or SCADA systems for remote monitoring and control.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 30000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 30000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Robot
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

  • Distribution automation systems solutions
    What are the difficulties in overhead line operation and maintenance?Difficulty one:Overhead lines of distribution network have wide coverage,complicatedterrain,many radiation branches and distributed power supply,resultingin "many line faults and difficulty in fault troubleshooting".Difficulty Two:Manual troubleshooting is time-consuming and laborious.Meanwhile,therunning current,voltage and switching state of the line cannot be graspedin real time,because of the lack of intelligent technical m
    04/22/2025
  • RW8000 DMS Distribution Management System Solutions
    OverviewNowadays, the development trend of power grid is intellectualization. As an important part of power grid, the power distribution system is very close to the customers and it has to run properly. The distribution management system (DMS)played an important role in it.Introduction:RW8000 power distribution management system (DMS) is designed for the smart grids. It is based on real-time application, centered on distribution network operation and management, focusing on the business process
    09/07/2023
  • High-Precision Electrical Parameter Monitoring System Solution
    1.Introduction​With the increasingly stringent requirements for power supply quality in high-end facilities such as precision manufacturing, medical diagnosis, and data centers, traditional power monitoring systems, due to their low sampling accuracy and weak data analysis capabilities, can no longer meet the demand for deep insight and precise management of power quality. In response, we are introducing a new generation ​High-Precision Electrical Parameter Monitoring System. With ​millisecond-l
    09/28/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.