CJX8(B) Series AC Contactor in 50/60Hz Circuits

  • CJX8(B) Series AC Contactor in 50/60Hz Circuits

Key attributes

Brand Switchgear parts
Model NO. CJX8(B) Series AC Contactor
Rated normal current 16A
Rated frequency 50Hz
Series CJX8(B)

Product descriptions from the supplier

Description

Application

CJX(B) series AC contactor is suitable for the circuit of AC 50Hz (or 60Hz), rated working voltage up to 660V and rated working current up to 370A, used to make and break circuit in a far distance, it also can be formed into an electromagnetic starter with suitable thermal overload relay to protect the circuit against
possible overload.

The products are in conformity with such standards as GB 14048.4 and IEC 60947-4-1.

Main Technical Data

Type

Frame code

Rated insulation Voltage

Conventional thermal current

Rated working current - 380V

Rated working current - 660V

Max power of controllable motor - 380V

Max power of controllable motor - 660V

Operating frequency time/h - AC-3

Operating frequency time/h - AC-4

CJX8(B)-9

16

690

16

8.5

3.5

4

3

600

300

CJX8(B)-12

16

690

20

11.5

4.9

5.5

4

600

300

CJX8(B)-16

16

690

25

15.5

3.7

7.5

5.5

600

300

CJX8(B)-25

25

690

40

22

13

11

11

600

300

CJX8(B)-30

30

690

45

30

17.5

15

15

600

300

CJX8(B)-37

45

690

45

37

21

18.5

18.5

600

300

CJX8(B)-45

45

690

60

44

25

22

22

600

300

CJX8(B)-65

85

690

80

65

44

33

40

600

300

CJX8(B)-85

85

690

100

85

55

45

50

600

300

CJX8(B)-105

105

690

140

105

82

55

75

600

150

CJX8(B)-170

170

690

230

170

118

90

110

600

150

CJX8(B)-250

250

690

300

245

170

132

160

400

100

CJX8(B)-370

370

690

410

370

268

200

250

400

100

External And Installation Size

Type

A

B max

C

D

E

F

G

H min

CJX8(B)-105

118

154

137

140

35

6.5

6.5

15

CJX8(B)-170

134

165

152

150

40

6

7.5

15

CJX8(B)-250

167

207

193

190

50

7

8.5

15

CJX8(B)-370

202

252

221

220

60

7

8.5

15


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.