Customization 15kV 30kV 33kV 34.5kV 36kV Three Phase Neutral Grounding/earthing Transformer direct supply

  • Customization 15kV 30kV 33kV 34.5kV 36kV Three Phase Neutral Grounding/earthing Transformer direct supply

Key attributes

Brand ROCKWILL
Model NO. Customization 15kV 30kV 33kV 34.5kV 36kV Three Phase Neutral Grounding/earthing Transformer direct supply
Rated voltage 36kV
Rated normal current 3000A
Rated frequency 50/60Hz
Series JDS

Product descriptions from the supplier

Description

Description

As a pioneer and the first dedicated original equipment manufacturer (OEM) in China's earthing transformer industry, we have laid the original benchmark for the industry's development with our profound technical strength accumulated through decades of intensive cultivation. From the independent R&D of core technologies to large-scale mass production, we have built a full-process independently controllable system. Relying on stable and leading product performance and unparalleled reliability, we have become a preferred partner in the field of power grid construction.

This grounding transformer, suitable for systems up to 36kV, is a specialized electrical device. It creates an artificial neutral point in power grids, playing a crucial role in grounding protection. By effectively handling single - phase ground faults, it ensures the stable operation of medium - voltage power systems, whether in urban distribution networks or industrial power setups.

Feature

  • Voltage Adaptability:Designed for up to 36kV systems, it matches the common voltage levels of medium - voltage power grids, ensuring wide - ranging applicability.

  • Fault Handling:Efficiently suppresses arc - grounding overvoltages during single - phase ground faults. It helps reduce ground fault currents, minimizing damage to power grid equipment and enhancing system reliability.

  • Robust Construction:Built with high - quality materials like premium magnetic cores and durable windings. The enclosure is sturdy, resisting harsh environmental factors such as moisture and dust, ensuring long - term stable performance.

  • Safety Enhancement:Provides a reliable neutral grounding solution, preventing abnormal voltage fluctuations and equipment insulation damage, thus safeguarding the safety of the entire power grid and connected electrical devices.

Main technical parameter

Some of these earthing transformers cover voltage levels including:3.3kV / 6kV / 11kV / 15kV / 20kV / 22kV / 30kV / 33kV / 34.5kV / 36kV / 44kV / 66kV / 88kV / 110kV / 132kV / 145kV / 150kV / 220kV / 275kV / 330kV / 400kV, etc. The current withstand time ranges from 1s, 2s, 3s, 5s, 6s, 8s, 9s, 10s, 30s, 60s, 1hour to 2hours, and customization is available.

Types

 oil-immersed [ZN(Zig-zag), ZNyn]

Voltage

Up to 36kV

Current

Up to 3000A

Duty (seconds)

10 / 30 / 60 or others

Cooling method

ONAN, ONAF; AN, AF

Frequency

50 / 60Hz

Installation

Indoor / Outdoor

Ambient Temperature

-25°C to 40°C

Standards

IEC 60076-6

IEC 60076-1

Enclosure Options

Transformer cabinets for any IP degreess with:

-CT

-VT

-Isolation switch

Note: This parameter table is for reference. We can offer customize production tailored to client specifications.

Scope of Application

Suitable for scenarios with varying capacities and voltage levels.

  • 35kV and Above Distribution Networks: Transformer windings typically adopt a star (Y) connection with an accessible neutral point, eliminating the need for grounding transformers.

  • 6kV and 10kV Distribution Networks: Transformer windings mostly use delta (Δ) connections without accessible neutral points, requiring grounding transformers to provide a neutral point.

Special Scenarios: When system unbalanced voltage is high, Z-type transformers can meet measurement requirements through balanced design of their three-phase windings. When system unbalanced voltage is low (e.g., fully cable-based networks), the neutral point of Z-type transformers must generate an unbalanced voltage of 30-70V to satisfy measurement criteria.

Purpose and Function: Provides a return path for fault currents, ensuring safety and stability during ground faults.

Operating Principle During Faults: During a ground fault, fault current flows through the transformer’s neutral point. The counteracting magnetic flux generated by reverse current neutralizes impedance.

Voltage and Current Ratings: Rated voltage matches the system’s line voltage. Capable of withstanding maximum fault currents for up to 30 seconds.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 108000m²m² Total staff: 700+ Highest Annual Export(usD): 150000000
Workplace: 108000m²m²
Total staff: 700+
Highest Annual Export(usD): 150000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding Electrodes
    Impact of DC Bias in Transformers at Renewable Energy Stations Near UHVDC Grounding ElectrodesWhen the grounding electrode of an Ultra-High-Voltage Direct Current (UHVDC) transmission system is located close to a renewable energy power station, the return current flowing through the earth can cause a rise in ground potential around the electrode area. This ground potential rise leads to a shift in the neutral-point potential of nearby power transformers, inducing DC bias (or DC offset) in their
    01/15/2026
  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Distribution Equipment Transformer Testing, Inspection, and Maintenance
    1.Transformer Maintenance and Inspection Open the low-voltage (LV) circuit breaker of the transformer under maintenance, remove the control power fuse, and hang a “Do Not Close” warning sign on the switch handle. Open the high-voltage (HV) circuit breaker of the transformer under maintenance, close the grounding switch, fully discharge the transformer, lock the HV switchgear, and hang a “Do Not Close” warning sign on the switch handle. For dry-type transformer maintenance: first clean the porcel
    12/25/2025
  • How to Test Insulation Resistance of Distribution Transformers
    In practical work, insulation resistance of distribution transformers is generally measured twice: the insulation resistance between thehigh-voltage (HV) windingand thelow-voltage (LV) winding plus the transformer tank, and the insulation resistance between theLV windingand theHV winding plus the transformer tank.If both measurements yield acceptable values, it indicates that the insulation among the HV winding, LV winding, and transformer tank is qualified. If either measurement fails, pairwise
    12/25/2025
  • Design Principles for Pole-Mounted Distribution Transformers
    Design Principles for Pole-Mounted Distribution Transformers(1) Location and Layout PrinciplesPole-mounted transformer platforms should be located near the load center or close to critical loads, following the principle of “small capacity, multiple locations” to facilitate equipment replacement and maintenance. For residential power supply, three-phase transformers may be installed nearby based on current demand and future growth projections.(2) Capacity Selection for Three-Phase Pole-Mounted Tr
    12/25/2025
  • Transformer Noise Control Solutions for Different Installations
    1.Noise Mitigation for Ground-Level Independent Transformer RoomsMitigation Strategy:First, conduct a power-off inspection and maintenance of the transformer, including replacing aged insulating oil, checking and tightening all fasteners, and cleaning dust from the unit.Second, reinforce the transformer foundation or install vibration isolation devices—such as rubber pads or spring isolators—selected based on the severity of vibration.Finally, strengthen sound insulation at weak points of the ro
    12/25/2025

Related Solutions

  • Intelligent Operation Solution for 12kV Vacuum Circuit Breakers: Integrating Real-time Monitoring & Lifetime Optimization
    Ⅰ. Equipment Operation & MaintenanceIntelligent Monitoring System Integration​Multi-parameter Real-time Monitoring: Embedded sensors (temperature, displacement, Hall effect current sensors) track contact temperature rise, mechanical characteristics (opening/closing speed, overtravel), coil current, and partial discharge signals. Data undergoes preprocessing via edge computing prior to cloud upload.​Lifetime Prediction Model: Dynamically evaluates remaining lifespan using electrical wear data
    06/10/2025
  • SF6 Circuit Breaker Solutions for Outdoor Installation (Anti-Pollution & Seismic Resistance)
    I.Core Challenges in Outdoor Installation​In high-voltage transmission and distribution systems, SF6 circuit breakers are exposed to complex outdoor environments for extended periods, facing the following critical issues:​Pollution & Insulation Degradation​Dust, salt fog, and industrial pollutants in outdoor environments easily adhere to equipment surfaces. In coastal or industrial areas, pollution levels may reach ​Class IV, resulting in insufficient creepage distance and triggering ​flasho
    05/12/2025
  • 12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact Design
    12kV Indoor Vacuum Circuit Breaker Southeast Asia Solution: Anti-Corrosion Compact DesignⅠ. Executive Summary​Southeast Asia faces rapidly growing electricity demand alongside environmental challenges including high temperatures, humidity, salt spray corrosion, and grid instability. This solution recommends ​Solid Insulated Pole-Mounted Vacuum Circuit Breakers (VCB)​​ featuring ​high reliability, ​compact design, and ​smart monitoring. Tailored for tropical climates and industrial scenarios, it
    06/10/2025
Related Free tools
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.