Description

Description

DC molded case circuit breakers are suitable for circuits with a rated operating voltage up to DC1500V, a rated insulation voltage of 1500V, a rated impulse withstand voltage of 12kV, and a rated current ranging from 10A to 630A. They can be installed either vertically or horizontally and are resistant to environments containing humid air, salt spray, oil mist, mold, and the like.

Product Features

  • The GYM7DC series DC molded case circuit breaker (hereinafter referred to as "circuit breaker") has a rated operating voltage up to DC1500V, a rated insulation voltage of 1500V, a rated impulse withstand voltage of 12kV, and a rated current ranging from 10A to 630A.

  • This circuit breaker can be installed vertically (i.e., vertical installation) or horizontally (i.e., horizontal installation).

  • This circuit breaker complies with the following standards:

  • IEC 60947-1 and GB/T 14048.1 (General Rules)

  • IEC 60947-2 and GB/T 14048.2 (Low-Voltage Circuit Breakers)

Technical Parameter

Rated Operating Voltage
Ue(V,AC)
DC250V DC1000V DC1500V DC1500V DC1500V
Rated insulation voltage
Ui (V):
1000V 1500V 1600V 1600V 1600V
Rated Shock Withstand Voltage
Uimp (kV):
0.8kV 0.8kV 1.2kV 1.2ky 1.2ky
Rated Operating Short Circuit Segmentation Capability
LCS (%LCU)
DC110V 35kA



DC250V 25kA



DC500V
35kA


DC750V
25kA 85kA 85kA 85kA
DC1000V
15kA 50kA 50kA 50kA
DC1200V

35kA 35kA 35kA
DC1500V

20kA 20kA 20kA
Rated Limit Short-Circuit Segmentation
Capability lcu
(kA):
DC110V 35kA



DC250V 25kA



DC500V
35kA


DC750V
25kA 85kA 85kA 85kA
DC1000V
15kA 50kA 50kA 50kA
DC1200V

35kA 35kA 35kA
DC1500V

20kA 20kA 20kA
Operational
performance
(times)
Electrical examination 5000 times 2000 times DC1000V2000 times
DC1500V1000 times
DC1000V2000 times
DC1500V1000 times
DC1000V2000 times
DC1500V1000 times
Mechanical examination Exemption from maintenance and examination 10,000 times 10,000 times 10,000 times 10,000 times 10,000 times
It can maintain the life of the exam 20,000 times 20,000 times 20,000 times 15,000 times 15,000 times

Normal working conditions

  • For altitudes of 2000m and below, the capacity reduction coefficient at high altitude is shown in the volume reduction coefficient table;

Model Shell Grade Current Rating (A) 50℃ 55℃ 60℃ 65℃ 70℃
GYM7DC-125/2300 250  0.95  0.93  0.91  0.88 
GYM7DC-250/2300 250  0.95  0.93  0.91  0.88 
GYM7DC-320/2300 250  0.95  0.93  0.91  0.88 
GYM7DC-400/2300 400  0.93  0.91  0.89  0.85 
GYM7DC-630/2300 630  0.92  0.90  0.89  0.83 
  • Storage temperature -40°C ~+75°C;

  • The relative humidity of the air at the installation site should not exceed 50% at the temperature of +40°C, and it can be at lower temperaturesHigher relative humidity, e.g. 90% at 20°C. Measures should be taken against occasional condensation due to temperature changes;

  • TH (three-proof type) meets the requirements of GB/T2423.4 and GB/T2423.18 standards, and can withstand humid air, salt spray,the influence of oil mist and mold;

  • The inclination is ±22.5°;

  • In a medium without explosion hazard, and the medium is not enough to corrode the metal and destroy the insulation of gas and conductive dust Place;

  •  In a place where there is no rain and snow.

Product Dimensions

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • Rockwill Passes Single-Phase Ground Fault Test for Smart Feeder Terminal
    Rockwill Electric Co., Ltd. has successfully passed the real-scenario single-phase-to-ground fault test conducted by the Wenzhou of China Electric Power Research Institute for its DA-F200-302 hood-type feeder terminal and integrated primary-secondary pole-mounted circuit breakers—ZW20-12/T630-20 and ZW68-12/T630-20—receiving an official qualified test report. This achievement marks Rockwill Electric as a leader in single-phase ground fault detection technology within distribution networks.The DA
    12/25/2025
  • Case Studies of Installation and Manufacturing Defects in 110kV HV Circuit Breaker Porcelain Insulators
    1. SF6 gas leakage occurred in the ABB LTB 72 D1 72.5 kV circuit breaker.Inspection revealed gas leakage at the fixed contact and cover plate area. This was caused by improper or careless assembly, where the dual O-rings slipped and were misplaced, resulting in gas leakage over time.2. Manufacturing Defects on the Outer Surface of 110kV Circuit Breaker Porcelain InsulatorsAlthough high-voltage circuit breakers typically have their porcelain insulators protected with covering materials during tra
    12/16/2025
  • Overview of Defect Diagnosis Methods for High-Voltage AC Circuit Breakers
    1. What are the characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms? How to extract these characteristic parameters from the original trip coil current signal?Answer: The characteristic parameters of the coil current waveform in high-voltage circuit breaker operating mechanisms may include the following: Steady-state peak current: The maximum steady-state current value in the electromagnet coil waveform, representing the position where the
    12/16/2025
  • A Brief Discussion on the Issues of Converting Reclosers into Outdoor Vacuum Circuit Breakers for Use
    The rural power grid transformation plays an important role in reducing rural electricity tariffs and accelerating rural economic development. Recently, the author participated in the design of several small-scale rural power grid transformation projects or conventional substations. In rural power grid substations, conventional 10kV systems mostly adopt 10kV outdoor auto circuit vacuum reclosers.To save investment, we adopted a scheme in the transformation that removes the control unit of the 10
    12/12/2025
  • A Brief Analysis of Automatic Circuit Recloser in Distribution Feeder Automation
    An Automatic Circuit Recloser is a high-voltage switching device with built-in control (it inherently possesses fault current detection, operation sequence control, and execution functions without requiring additional relay protection or operating devices) and protective capabilities. It can automatically detect the current and voltage in its circuit, automatically interrupt fault currents according to inverse-time protection characteristics during faults, and perform multiple reclosures accordi
    12/12/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.