• DS16 126kV 252kV 363kV 420kV 550kV High voltage disconnect switch
DS16 126kV 252kV 363kV 420kV 550kV High voltage disconnect switch
discuss personally
Model
DS16B-550/4000-63
DS16B-550/3150-50
DS16B-420/3150-50
DS16B-363/5000-63
DS16B-363/3150-50
DS16B-252/5000-63
DS16B-252/3150-50
DS16B-126/3150-40
DS16B-126/2500-40
Basic info
Brand ROCKWILL
Model NO. DS16 126kV 252kV 363kV 420kV 550kV High voltage disconnect switch
Rated voltage 550kV
Rated normal current 4000A
Series DS16
Product Detail

Description:

DS16 series disconnector adopts single-column single-arm vertical telescopic structure, which is mainly composed of base, insulator, conductive system, operating mechanism, etc. The disconnector is operated by CJ11 motor operating mechanism for opening and closing. The attached ground switch is mainly composed of ground switch system and operating mechanism, and each group of ground switches is operated by a CJ11 motor operating mechanism for opening and closing.


Main Features:

 

  •  Simple and compact structure, small footprint.

  • Strong product flow capacity, long mechanical life.

  • Optimized spring design, light and smooth operation.

  •  High seismic performance, can resist nine degrees of earthquake intensity.

  • The layout is flexible, convenient for users to choose.

Technical parameter

 

image.png

 

What are the operation modes of the disconnector?

Operation Methods:

  • Manual: Manual isolator switches are simple to operate and cost-effective. They are suitable for applications where operations are infrequent, speed is not critical, and operators can easily access the site.

  • Electric: Electric isolator switches are ideal for large substations and environments that require a high degree of automation. They enable remote control and automated operations but come with higher costs and the need for a stable power supply and complex control systems.

  • Pneumatic: Pneumatic isolator switches offer rapid and powerful operation, making them suitable for applications requiring high-speed operation and explosion-proof environments (such as chemical plants and refineries). However, they require a compressed air system.

Operation Frequency:

If the isolator switch needs to be operated frequently, it is important to consider its mechanical life and the reliability of the operating mechanism. For example, in substations where frequent switching operations are required, it is advisable to select isolator switches with long mechanical life and reliable, flexible operating mechanisms to reduce maintenance costs and the incidence of failures.

 

Know your supplier
ROCKWILL
Rockwill Electric Group Global Manufacturer of High voltage and medium-voltage power equipment and smart grid solutions. Headquartered in Wenzhou, China. Serving 100+ countries with quality, innovation, and trust. What We Offer: • HV-MV switchgear (VCB, SF₆ circuit breakers, RMU, GIS) • Distribution transformers and substations • Smart grid and monitoring systems • Solar, wind, EV charging, and energy storage solutions • EPC turnkey power projects Certified: ISO 9001 / ISO 14001 / ISO 45001
Main Categories
High Voltage Electrical Apparatus
Business Type
Design/Manufacture/Sales
Highest Annual Export (USD)
$150,000,000
Professional Experience
16 years
Workplace
108000m²m²
占位
占位
Related Products
Related Knowledges
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
Cost Differences and Performance Comparison of 35kV New Energy Transformers Based on Dry-Type, Mineral Oil, and Vegetable Oil
For users, when purchasing a 35kV new energy transformer, choosing between dry-type, mineral oil-filled, or vegetable oil-filled types involves multiple considerations. These include user habits, maintenance-free performance, safety and fire resistance, volume and weight, among others. However, cost differences are undoubtedly one of the most crucial factors.To illustrate the issue intuitively, this paper selects a three-level energy efficiency dual-winding new energy transformer with a rated ca
Ron
07/26/2025
What is the connection group of a transformer?
What is the connection group of a transformer?
Transformer Connection GroupThe connection group of a transformer refers to the phase difference between the primary and secondary voltages or currents. It is determined by the winding directions of the primary and secondary coils, the labeling of their start and end terminals, and the connection mode. Expressed in a clock-like format, there are 12 groups in total, numbered from 0 to 11.The DC method is commonly used to measure the transformer's connection group, mainly to verify whether the con
Vziman
07/26/2025
Working Voltage in Power System
Working Voltage in Power System
Working VoltageThe term "working voltage" refers to the maximum voltage that a device can withstand without sustaining damage or burning out, while ensuring the reliability, safety, and proper operation of both the device and associated circuits.For long-distance power transmission, the use of high voltage is advantageous. In AC systems, maintaining a load power factor as close to unity as possible is also economically necessary. Practically, heavy currents are more challenging to handle than hi
Encyclopedia
07/26/2025
What is Steady State Stability in Power System?
What is Steady State Stability in Power System?
Definition of Steady State StabilitySteady state stability is defined as the capability of an electric power system to sustain its initial operating condition following a small disturbance, or to converge to a state closely approximating the initial condition when the disturbance persists. This concept holds critical significance in power system planning and design, the development of specialized automatic control devices, the commissioning of new system components, and the adjustment of operati
Edwiin
07/26/2025
What is the sequence for powering down the transformer?
What is the sequence for powering down the transformer?
The sequence for shutting down a main transformer is as follows: when de-energizing, the load side should be shut down first, followed by the power supply side. For energizing operations, the reverse order applies: the power supply side is energized first, then the load side. This is because: Energizing from the power supply side to the load side makes it easier to identify the fault range and take prompt judgment and handling measures in case of a fault, preventing the fault from spreading or e
Rockwell
07/26/2025
What are the methods for switching operations of station transformers?
What are the methods for switching operations of station transformers?
Let's take an auxiliary power system with two station transformers as an example. When one station transformer needs to be out of service, there are two operation methods: non-interruptive power supply and instantaneous power interruption. Generally, the method of instantaneous power interruption on the low-voltage side is preferred.The operation method for instantaneous power interruption on the low-voltage side is as follows:Open the 380V power incoming circuit breaker of the corresponding sec
Vziman
07/26/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!