DTL Intermediate copper terminal

  • DTL Intermediate copper terminal

Key attributes

Brand Switchgear parts
Model NO. DTL Intermediate copper terminal
Nominal cross-sectional area 35mm²
Series DTL

Product descriptions from the supplier

Description

DTL intermediate copper terminal is a specially designed intermediate crimping connector for copper core wires and cables. Its core function is to achieve straight intermediate connection of copper conductors, and it is widely used in power distribution, industrial equipment wiring, new energy power stations and other scenarios. It is particularly suitable for copper conductor breakpoint repair, length extension and other needs, providing stable and reliable connection guarantee for copper material current transmission.
Core performance advantage: adaptable to multiple scenario applications
Efficient and stable conductivity: T2 copper material+symmetrical structural design ensures smooth current transmission path, with a contact resistance of ≤ 3m Ω (in accordance with GB/T 14315 standard). At rated current, the temperature rise at the connection point is ≤ 25K, far below the national standard limit, to avoid insulation aging or safety hazards caused by heat generation; ​
Strong mechanical firmness: After crimping, the terminal and copper conductor form a "metal interlocking" structure, with a tensile strength of ≥ 2 times the breaking force of the copper wire, able to withstand mechanical stress caused by line vibration, thermal expansion and contraction, and long-term use without loosening or breaking, ensuring stable operation of the power system; ​
Excellent corrosion resistance and durability: Tin plated terminals can withstand salt spray testing for over 480 hours, and can withstand harsh environments such as high salt spray along the coast and corrosive gases in industrial plants; Simultaneously capable of stable operation within the temperature range of -40 ℃ to 120 ℃, suitable for different climate scenarios such as low temperature in the north and high temperature in the south; ​
Easy and efficient installation: No welding required, only hydraulic crimping pliers (compatible with corresponding specifications of molds) are needed to complete the installation, with a single terminal crimping time of ≤ 3 minutes; The two end opening design facilitates quick positioning and threading by construction personnel, reduces construction error rates, and improves on-site construction efficiency.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.