• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Fused Distribution Cabinet

  • Fused Distribution Cabinet
  • Fused Distribution Cabinet

Key attributes

Brand Wone Store
Model NO. Fused Distribution Cabinet
Rated voltage 400V
Rated normal current 800A
Series AcuLok TMO

Product descriptions from the supplier

Description

The Lucy Electric AcuLok TMO range of transformer mounted low voltage distribution cabinets incorporates the unique AcuLok fuse handle system, which improves reliability and operator safety levels. Suitable for outdoor applications or indoor as part of a unit substation, the high equipment specification includes current transformers for load monitoring, a programmable digital meter, integral 660 A Veam Powerlock generator sockets and an RCD protected auxiliary socket.

features

  • Multi position attachment option for mechanical cable connectors on fuse stalks

  • Individual load-bearing cable cleat per fuse way

  • Easily removable fuse stalks for connector attachment

  • Complete 3 phase fuse ways are easily removable to allow panel reconfiguration

  • Live current measurement per fuse handle facility

  • 4, 5 or 6 outgoing fuse ways

  • 800 A or 1600 A busbar ratings

  • MCCBs up to 1600 A fitted to a chassis assembly

  • ACBs up to 2500 A directly connected to transformer flange

  • 3-phase disconnector handle

  • 4-core cable kit

Technical specifications

  1. Mounts on distribution transformers with 'F' type  f lange according to ENA technical specification 35-1

  2. 1000A / 2000A rated independent manual load  make / load break disconnectors

  3.  4, 5 or 6 outgoing fuse ways

  4. 630A rated fuse handles accept BS 88 J type fuses with 92mm centres

  5. 1 x 4 core 300mm2 Waveform cable per way  (bunched 185mm2 or 740mm2 for ACB’s)

  6. Outgoing connections by compression lugs or range  taking mechanical shear-off connectors 95-300mm2 capacity

  7. 660A Veam Powerlock standby generator sockets including earth

  8. Multi-function digital meter with 30 minute lag  setting and option for comms

  9. Metering CL0.5 rated current transformer per phase, ratio 2000/5A or 1000/5A

  10. 20VA CT burden

  11. 60% rated neutral

  12. Suitable for 3C or 4C networks

  13. IP2XB rating with the door open

  14. Operating temperature range -25 to +40°C

 

Documentation Resource Library
Restricted
Fused Distribution Cabinet Quick Start
Operation manual
English
Consulting
Consulting
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings/Instrument Transformer/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.