Key attributes

Brand Switchgear parts
Model NO. GPS8-01 Voltage Protector with Over and Under Voltage Funtion
Rated voltage AC220V
Rated normal current 32A
Rated frequency 45Hz-65Hz
Series GPS8-01

Product descriptions from the supplier

Description

The GPS8-01 Voltage Protector is specifically designed for household and basic industrial equipment, offering precise over-voltage and under-voltage protection. It supports a wide input voltage range from 80V to 400V, effectively addressing power grid fluctuations. With features such as low power consumption, self-resetting capability, and dual-bus wiring design, it ensures long-term stable operation and rapid fault recovery. Its compact DIN rail mounting and wide temperature adaptability from -20℃ ~ +60℃ make it especially suitable for applications like household appliances and small-scale power distribution systems—scenarios that do not require overcurrent protection but are sensitive to voltage anomalies. The GPS8-01 provides a cost-effective solution to ensure basic electrical safety.

GPS8-01 Self resetting Digital Voltage Protector Product Features:
1. High precision true effective value measurement
Using True RMS voltage sampling technology to accurately capture the actual voltage values under complex waveforms,
Prevent protection failure caused by misjudgment.
2. Full parameter programmable protection
Users can set overvoltage/undervoltage trigger thresholds (such as 170V-280V range), overcurrent values, and self reset delays (0-999 seconds) to adapt to different regional power grid characteristics and equipment requirements.
3. Strengthen electrical connection performance
Innovative dual busbar structure design provides stronger wiring carrying capacity and heat dissipation performance, ensuring long-term stable operation in high current scenarios.
4. Intelligent fault management mechanism
Equipped with self starting function, it automatically delays resetting after the voltage returns to normal, reducing manual intervention; The red green dual color LED provides real-time indication of operational/fault status, allowing for quick problem localization.
5. Industrial grade human-computer interaction
High brightness digital tube displays real-time voltage values clearly, paired with status indicator lights, achieving dual dimensional monitoring of "numerical+graphical"
6. Convenient integrated deployment
Standard 35mm guide rail installation design, seamlessly compatible with various distribution cabinets/boxes, greatly simplifying the construction process.

Technical parameters:

Model

GPS8-01 Voltage Protector

Function

Over and under voltage

Rated supply voltage

AC220V(L-N)

Rated supply frequency

45~65HZ

Operation voltage range

80V~400V(L-N)

Rated operational current

32A,40A,50A,63A,80A(AC1)

Burden

AC max.3VA

Over voltage operation value

OFF,230V~300V

Under voltage operation value

140V~210V,OFF

Over/under voltage action delay

0.1s~10s

Power-up delay

2s~600s

Reset time

2s~900s

Measurement error

≤1%

Electrical life(AC1)

1*104

Mechanical life

1*106

Operating temperature

-20℃ ~ +60℃

Storage temperature

-35℃ ~ +75℃

Mounting/DIN rail

Din rail EN/IEC 60715

Protection degree

IP40 for front panel/IP20 terminals

Operating position

any

Overvoltage category

Pollution degree

2

Dimensions

82x36x68mm

weight

135g

Documentation Resource Library
Restricted
GPS8-01 Voltage Protector
Catalogue
English
Consulting
Consulting
FAQ
Q: What are the core functions and advantages of the GPS8-01?
A:

The core functions and advantages focus on three dimensions: protection accuracy, installation adaptability, and ease of use:

·  Dual precise protection: Targets two major voltage abnormalities (overvoltage and undervoltage) with customizable protection thresholds and an action delay of only 0.5 seconds, quickly cutting off the fault circuit to avoid equipment insulation breakdown and component burnout.

·  Modular and convenient installation: 35mm standard DIN rail plug-and-play, compact size (82×36×68mm) and light weight (only 130g), allowing dense arrangement with circuit breakers and relays, saving distribution cabinet space and improving installation efficiency by 50%.

·  Humanized design: The digital display intuitively shows real-time voltage, and LED indicators quickly locate fault types (overvoltage/undervoltage); automatic reset after fault eliminates the need for manual closing, especially suitable for unattended scenarios with near-zero operation and maintenance costs.

· High reliability: Adopts dual-bus wiring design for stronger power supply stability; protection level reaches IP40 (front panel)/IP20 (terminals), with an operating temperature range of -20℃~+55℃, adapting to various usage environments.

Q: What is the GPS8-01 Voltage Protector?
A:

The GPS8-01 is a DIN rail-mounted over/under voltage protection device specially designed for household equipment and low-voltage power distribution systems, featuring dual protection of overvoltage and undervoltage. Adopting 1-MODULE standard DIN rail installation, it is compatible with AC 220V rated voltage and 45~65Hz frequency. The overvoltage protection threshold can be adjusted within 230V~300V (factory default 275V), and the undervoltage protection threshold within 145V~210V (factory default 175V), with an action delay of 0.5 seconds for both. It supports automatic reset (reset time adjustable 2s~900s) after fault elimination, equipped with digital voltage display and LED fault indicators, fully protecting electrical equipment from damage caused by voltage abnormalities.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Transformer Accidents and Light Gas Operation Issues
    1. Accident Record (March 19, 2019)At 16:13 on March 19, 2019, the monitoring background reported a light gas action of No. 3 main transformer. In accordance with the Code for Operation of Power Transformers (DL/T572-2010), operation and maintenance (O&M) personnel inspected the on-site condition of No. 3 main transformer.On-site confirmation: The WBH non-electrical protection panel of No. 3 main transformer reported a Phase B light gas action of the transformer body, and the reset was ineff
    02/05/2026
  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.