Key attributes

Brand MV Switchgear Accessories
Model NO. Level Control Relay GRL8-01 02
Rated frequency 50/60Hz
Series GRL8

Product descriptions from the supplier

Description

The GRL8-01/02 series is an intelligent control relay designed specifically for liquid level monitoring, utilizing isolated power supply technology and modular structure. Its compact 18mm width body supports 35mm standard card rail installation, suitable for automation control scenarios of various liquid storage and transportation systems.

GRL8-01/02 series liquid level control relay product features:
1. Dual mode flexible configuration
Type 01 supports 2-pole liquid level control
Type 02 supports 2-pole or 2-pole liquid level control
2. Programmable working mode
Free selection of drainage mode (triggered by high liquid level) or water supply mode (triggered by low liquid level) through dip switch
3. Precision parameter adjustment
Sensitivity 5-100k Ω continuously adjustable, suitable for liquids with different conductivities
The action delay can be set between 0.1s-10s, effectively suppressing interference from liquid level fluctuations
4. Wide voltage compatible design
Supports AC/DC 24~240V wide input, isolated power supply enhances system safety
5. Visual state management
Two color LED indicator lights display real-time power supply status and relay action signals
6. Industrial grade compact structure
35mm rail installation in accordance with DIN EN 60715 standard, 18mm ultra-thin width saves control cabinet space

Advantages of GRL8-01/02 series liquid level control relay products:
1. Multi purpose: A single device is compatible with both water supply and drainage modes, reducing the variety of spare parts
2. Anti interference design: adjustable delay function effectively filters false signals and improves action reliability
3. Strong compatibility: wide voltage input+wide impedance range suitable for mainstream liquid level sensors worldwide
4. Convenient maintenance: Modular plug-in design supports quick on-site replacement, LED dual indication reduces the difficulty of fault diagnosis
5. Security Enhancement: The isolated power supply design prevents induced electrical interference and complies with industrial control safety standards

Technical parameters GRL8-01 GRL8-02
Function 2 level contorl mode 2 or 1 level contorl mode
Supply terminals A1-A2
Voltage range AC/DC 24-240V(50-60Hz)
Input max.2VA
Supply voltage tolerance -15%;+10%
Sensitivity ( input resistance) adjustable in range 5 kΩ -100 kΩ
Voltage in electrodes max. AC 5 V
Current in probe AC <0.1 mA
Time response max. 400 ms
Max. capacity length 800 m (sensitivity 25k&Omega;), 200 m (sensitivity 100 k&Omega;)
Max. capacity of probe cable 400 nF (sensitivity 25k&Omega;), 100 nF (sensitivity 100 k&Omega;)
Time delay (t) adjustable, 0.1 -10 s
Accuracy in setting (mechanical) &plusmn; 10 %
Temperature coefficient 0.05%/℃,at=20℃(0.05%℉,at=68℉)
Output 1&times;SPDT
Current rating 1&times;10A(AC1)
Switching voltage 250VAC/24VDC
Min.breaking capacity DC 500mW
Output indication red LED
Mechanical life 1&times;107
Electrical life(AC1) 1&times;105
Reset time max.200ms
Operating temperature -20℃ to+55℃(-4℉to131℉)
Storage temperature -35℃ to+75℃(-22℉to158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage cathegory III.
Pollution degree 2
Max.cable size(mm 2) solid wire max.1&times;2.5or 2&times;1.5/with sleeve max.1&times;2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90&times;18&times;64mm
Weight 70g 72g
Standards EN 60255-1
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Main Components of a Transformer – Operating Principle, Faults, and Phenomena of the Gas Relay
    Gas accumulation: Free gas is present in the transformer oil. Response: The gas in the liquid rises and accumulates in the Buchholz relay, compressing the transformer oil. As the liquid level drops, the float also descends. The movement of the float drives a switch element (magnetic contact), thereby triggering an alarm signal. However, the float is not affected, because a certain amount of gas can flow through the pipe into the storage chamber.Fault: Due to leakage causing loss of transformer o
    11/27/2025
  • Relay Protection Types in Substations: A Complete Guide
    (1) Generator Protection:Generator protection covers: phase-to-phase short circuits in stator windings, stator ground faults, inter-turn short circuits in stator windings, external short circuits, symmetrical overload, stator overvoltage, single- and double-point grounding in the excitation circuit, and loss of excitation. Tripping actions include shutdown, islanding, limiting fault impact, and alarm signaling.(2) Transformer Protection:Power transformer protection includes: phase-to-phase short
    11/05/2025
  • Sealing Structure for Oil-Filled SF6 Gas Density Relay Contact Lead Wires
    I. CLAIMS A sealing structure for lead wires of contacts in an oil-filled SF6 gas density relay, characterized by comprising a relay housing (1) and a terminal base (2); the terminal base (2) comprising a terminal base housing (3), a terminal base seat (4), and conductive pins (5); the terminal base seat (4) being disposed inside the terminal base housing (3), the terminal base housing (3) being welded onto the surface of the relay housing (1); a central through-hole (6) being provided at the ce
    10/27/2025
  • SF6 Density Relay Oil Leakage: Causes, Risks & Oil-Free Solutions
    1. Introduction SF6 electrical equipment, renowned for its excellent arc-quenching and insulating properties, has been widely applied in power systems. To ensure safe operation, real-time monitoring of SF6 gas density is essential. Currently, mechanical pointer-type density relays are commonly used, providing functions such as alarm, lockout, and on-site display. To enhance vibration resistance, most of these relays are filled internally with silicone oil.However, oil leakage from density relays
    10/27/2025
  • ZDM Oil-Free SF6 Density Relay: The Permanent Solution to Oil Leakage
    The 110kV substation at our plant was constructed and put into operation in February 2005. The 110kV system employs ZF4-126\1250-31.5 type SF6 GIS (Gas-Insulated Switchgear) from Beijing Switchgear Factory, comprising seven bays and 29 SF6 gas compartments, including five circuit breaker compartments. Each circuit breaker compartment is equipped with an SF6 gas density relay. Our plant uses the MTK-1 model oil-filled density relays manufactured by Shanghai Xinyuan Instrument Factory. These relay
    10/27/2025
  • On-Site Testing of SF6 Gas Density Relays: Relevant Issues
    IntroductionSF6 gas is widely used as an insulating and arc-quenching medium in high-voltage and extra-high-voltage electrical equipment due to its excellent insulation, arc-extinguishing properties, and chemical stability. The insulation strength and arc-quenching capability of electrical equipment depend on the density of SF6 gas. A decrease in SF6 gas density can lead to two main hazards: Reduced dielectric strength of the equipment; Decreased interrupting capacity of circuit breakers.Additio
    10/27/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.