• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


HA Outdoor waterproof Distribution Box

  • HA Outdoor waterproof Distribution Box
  • HA Outdoor waterproof Distribution Box

Key attributes

Brand Switchgear parts
Model NO. HA Outdoor waterproof Distribution Box
Mounting type Exposed installation
Series HA

Product descriptions from the supplier

Description

Body material: ABS

Transparent door: PC

Material characteristics: Impact, heat, low temperature, chemical resistance, excellent electrical performance and surface gloss, etc.

Certificates: CE, ROHS

Protection grade: IP65

Application: Suitable for indoor and outdoor electric, communication, fire fighting apparatus, iron and steel smelting, petrochemical industry, electron, power system, railway, building, mine, air and seaport, hotel, ship, works, wastewater treatment equipment, environmental equipment, and so on

Installation: 1, inside: There are din rail inside for din-rail type circuit breakers, an early bar, and a natural bar for cable connection
2,0utside: The products can be directly fixed on the wall or other flat boards with screws or nails via the screw holes in the base.

Outlet hole: The plastic plate in the hole can be knocked off for cables.

Model Code

Outside Dimension (mm)

G. Weight

N. Weight

Qty/Carton

Carton Dimension

L

W

H

CHA-MS 4WAY

112

200

95

12

8.7

30

51x36x42.5

CHA-MS 6WAY

148

200

95

14.9

11.5

30

51x42.5x48.5

CHA-MS 8WAY

184

200

95

16.7

12.8

30

52x42.5x58.5

CHA-MS 10WAY

222

200

95

13.0

9.8

20

51x43x47.5

CHA-MS 12WAY

256

200

95

14.8

11.5

20

51x43x54

CHA-MS 15 WAY

310

200

95

12.8

9.9

15

51x33x63.5

CHA-MS 18WAY

365

222

95

15.2

12.8

15

52.5x38x70

CHA-MS 24WAY

271

325

97

13.2

10.3

10

53.5x34x56.5

CHA-MS 36WAY

271

462

100

19

14.8

5

54.5x28.5x48

HA IP65


4way

ABS without terminal

8 way

ABS without terminal

12 way

ABS without terminal

18 way

ABS without terminal

24 way

ABS without terminal

HT IP65


5way

ABS without terminal

8 way

ABS without terminal

12 way

ABS without terminal

15 way

ABS without terminal

18 way

ABS without terminal

24 way

ABS without terminal

FAQ
Q: What is the protection class of the HA Outdoor Waterproof Distribution Box and what does it specifically mean?
A:

The protection class is IP65, where "6" means complete dust - tight protection and "5" means resistance to low - pressure water jets (such as heavy rain). It is suitable for outdoor, industrial humid and other scenarios and meets the IEC 60529 standard.

Q: What material is the box made of and what are its advantages?
A:

The box panel is made of ABS engineering plastic, and the transparent cover is made of PC material, which has the characteristics of impact resistance, corrosion resistance, aging resistance and strong insulation. Some models can choose stainless steel material, which is suitable for harsh outdoor environments.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.