• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


High frequency online UPs power supply (Single phase/220V)

  • High frequency online UPs power supply (Single phase/220V)

Key attributes

Brand Switchgear parts
Model NO. High frequency online UPs power supply (Single phase/220V)
Rated frequency 50/60Hz
Output Voltage 200-240VAC
Capacity 1kVA
Series HBG

Product descriptions from the supplier

Description

The HBG series fully embodies the essence of cuting-edge technology. The whole machine adopts the world's mostadvanced DSP digital control technology and ultra-high frequency control technology to create a small size, light weight and highwork eficiency; zero conversion design and pure sine wave The output technology ensures that the user device is suitable for avariety of devices. A unigue AC-DC conversion circuit is used to detect the output current and output voltage of the commercialpower supply, and through the high-frequency pulse width modulator, the current waveform of the input power supply is consistenwith the voltage waveform phase, so as to achieve a high input power factor areater than 95%.. Under normal conditions of themains, the mains obtains the DcBuS DC voltage through the Ac-Dc circuit, and then converts the DcBuS to 220V AC outputthrough the inverter. wave power. The excellent lGBT is used as the power conversion element. Due to the high-freguencyswitching characteristics of the lBGT, the operating frequency of the UPS inverter can reach 40KHz. The working eficiency of theinverter is improved, and the eficiency of the UPS is also improved. The noise of the inverter is reduced, so that the HBG seriesUPS can be placed directly in the computer room without affecting your work. online high-freguency HBG series UPsthrough the RS232 flood interface with power monitoring software, connect the UPs with the network server. providebower status at any time: and realize timind self-check, automaic storage, automatic timina switch machine and record poweStatus and other inteligent functions to achieve zero distance beween man-machine communication, When the utility power isinterrupted, the UPS will notify the server to prepare for shutdown, automatically save all data to disk, and execute the normashutdown command. Even in an unmanned network environment, the data security of the network system can be guaranteed

Features

True online double conversion
Input power factor correction
Output power factor up to 0.8
Ultra-wide mains input range(110V-300V)
Efficient frequency conversion mode OEcO mode provides energy saving effect (only for 1-3K models)
Compatible generator input
Long-term model charging current up to 6A
Optional sophisticated SNMP card can be used alone or with USB
Perfect monitoring with RS232
Simple operation control through display
And comprehensive display monitoring UPS status

Application field

Widely used in important data fields such as network management centers and computer centers, banking and securities, taxation, communication, postal services, broadcasting and television, public security, transportation, electricity, healthcare, industrial control, and national defense.

Technical Parameter

Model Specification HBG-1kH(S) HBG-2kH(S) HBG-3kH(S) HBG-6kH(S) HBG-10kH(S)
Phase Single Phase Input and Output        
Capacity 1000 VA / 800 W 2000 VA / 1600 W 3000 VA / 2400 W 6000 VA / 4800 W 10000 VA / 8000 W
Input          
Voltage Range 110 - 300VAC at 50% load; 160 - 300 VAC at 100% load 110 - 300VAC at 50% load; 176 - 300 VAC at 100% load      
Frequency Range 40Hz ~ 70 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 Hz      
Power Factor ≥ 0.99 at 100% load ≥ 0.99 at 100% load      
Output          
Output Voltage 200/208/220/230/240VAC 208/220/230/240VAC      
Voltage Range (Battery Mode) ± 1% ± 1%      
Frequency Range (Synchronous Correction Range) 47 ~ 53 Hz or 57 ~ 63 Hz 46Hz ~ 54 Hz or 56Hz ~ 64 Hz      
Frequency Range (Battery Mode) 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz      
Crest Factor 3:1 3:1      
Ripple Distortion ≤ 3% THD (Linear Load); ≤6% THD (Non-linear Load) ≤ 3% THD (Linear Load); ≤5% THD (Non-linear Load)      
Harmonic Distortion 0 0      
Conversion Time          
AC to DC 4 ms (Standard Conditions) 0      
Inverter to Bypass          
Waveform (Battery Mode) Pure Sine Wave        
Efficiency          
Mains Mode 88% 89% 90% 92% 93%
Battery Mode 83% 87% 89% 89% 91%
Battery          
Standard Unit          
Battery Model 12V / 7AH 12V / 7AH 12V / 7AH 12V / 7AH 12V / 7AH
Quantity (Cells) 2 4 6 12 16
Maximum Charging Current 1.0A (Max) 1.0A (Max) 1.0A (Max) Preset:1.0 A, Max:2.0A Preset:1.0 A, Max:2.0A
Charging Voltage 27.3VDC ± 1% 54.7VDC ± 1% 82.1VDC ± 1% 163.8VDC ± 1% 218.4VDC ± 1%
Long-term Unit     Depends on Power Supply Time    
Battery Model   6 6 16 16
Quantity (Cells) 3 6 8 16 16
Maximum Charging Current 1.0A/2.0A/4.0A/6.0 A 1.0A/2.0A/4.0A/6.0 A 1.0A/2.0A/4.0A/6.0 A Preset:4.0 A ± 10%, Max:6.0A ± 10% Preset:4.0 A ± 10%, Max:6.0A ± 10%
Charging Voltage 41.0VDC ± 1% 82.1VDC ± 1% 109.4VDC ± 1% 218.4VDC ± 1% 218.4VDC ± 1%
Appearance          
LCD or LED Display Load Size, Battery Capacity, Mains Mode, Battery Mode, Bypass Mode, Fault Indication        
Alarm          
Battery Mode Beeps every 4 seconds        
Low Battery Beeps every 1 second        
Overload Beeps every 0.5 second        
Error Continuous Beep        
External Dimensions          
Standard Unit          
Dimensions (W×D×H)mm 145 X 282 X 220 145 X 397 X 220 190 X 421 X 318 190 x 369 x 688 190 x 442 x 688
Net Weight (kgs) 9.8 17 27.6 43 63
Long-term Unit          
Dimensions (W×D×H)mm 145 X282 X 220 145 X397 X 220   190 x369 x 318 190 x442 x 318
Net Weight (kgs) 4.1 6.8 7.4 12 16
Operating Environment          
Temperature and Humidity Relative Humidity 20-90% and Temperature 0-40°C (No Condensation) Relative Humidity 0-95% and Temperature 0-40°C (No Condensation)      
Noise Less than 50dB@ 1m Less than 55dB @ 1m      
Control Management          
Smart RS-232 / USB Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8, Linux, Unix, and MAC        
Optional SNMP Power Management Supports SNMP Management and Network Management        

When the UPS is set to constant voltage and frequency mode, the output power will be derated by 40%. When the UPS output voltage is set to 208VAC, the output power will be derated by 10%. "S" represents the long-life model. When the internal battery count is changed to 16-19 units, the machine will derate the output according to the following formula: P=Prating × (N/20 × 100%). If the machine is installed at an altitude exceeding 1,000 meters, the output power will be derated by 1% for every 100-meter increase in elevation. Any changes to current product specifications will not be separately notified

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.