High Voltage Current-Limiting Fuse(For full range&transformer protection)

  • High Voltage Current-Limiting Fuse(For full range&transformer protection)
  • High Voltage Current-Limiting Fuse(For full range&transformer protection)

Key attributes

Brand Wone
Model NO. High Voltage Current-Limiting Fuse(For full range&transformer protection)
Rated voltage 7.2kV
Rated normal current 100A
Breaking capacity 63kA
Series Current-Limiting Fuse

Product descriptions from the supplier

Description

Characteristic brief :

  • Rated voltage from 7.2KV to 40.5KV.

  • Wide range of rated current from 6.3A to 200A.

  • Full range performance options available at 12KV and 24KV.

  • Powerful pyrotechnic or spring striker.

  • H.R.C.

  • Gurrent-limiting.

  • Low power dissipation,low temperature rise.

  • Operation extremely quickly,high reliability.

  • With primary coil of transformer in series.

  • Isolating & protecting transformer.

  • Conforming to standards: GB15166.2 DIN43625 BS2692-1 IEC60282-1.

Model illustration:

企业微信截图_17338104044634.png

Technical Parameters:

企业微信截图_17338105507832.png

企业微信截图_17338106475852.png

External&installation dimensions(Unit:tmm)


企业微信截图_17338107374503.png

XRNT Fuse link

企业微信截图_17338107428451.png


XRNT -12KV/ Fuse base

企业微信截图_17338107481513.png

XRNT -40.5KV/ Fuse base

What are the structural features of the high-voltage current-limiting fuses (for the full range and transformer protection)?

Fusible Element Structure:

  • The fusible element is a critical component, typically made from materials with high conductivity and a low melting point, such as silver or copper alloys. Its design is intricate, often featuring multiple narrowed sections that will melt first when subjected to overload or short-circuit currents. This design enables the fuse to respond rapidly to fault currents, effectively limiting the rise in current.

Arc-Quenching Medium and Device:

  • The interior is filled with arc-quenching media such as quartz sand. Quartz sand possesses excellent insulation and thermal conductivity properties. When the fusible element melts and an arc is generated, the quartz sand absorbs the heat from the arc, rapidly cooling and extinguishing it, thereby interrupting the current flow and preventing damage from sustained arcing.

Enclosure Material and Sealing:

  • The enclosure is generally made from high-strength ceramics or composite insulating materials. Ceramic enclosures offer superior insulation performance and mechanical strength, capable of withstanding the pressure generated during internal arc quenching. Additionally, the excellent sealing performance prevents external environmental factors (such as moisture and dust) from affecting the internal arc-quenching medium and the fusible element.


Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 65666m²m² Total staff: 300+ Highest Annual Export(usD): 50000000
Workplace: 65666m²m²
Total staff: 300+
Highest Annual Export(usD): 50000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: Wire cable/High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/New energy/Tester/Integrated Electrical Equipment/Production equipment/Generator/Electrical fittings
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.