• Product
  • Suppliers
  • Manufacturers
  • Solutions
  • Free tools
  • Knowledges
  • Experts
  • Communities
Search


Horn shaped copper terminal block

  • Horn shaped copper terminal block

Key attributes

Brand Switchgear parts
Model NO. Horn shaped copper terminal block
Nominal cross-sectional area 4mm²
Series DTGB

Product descriptions from the supplier

Description

The core value of horn mouth copper terminal blocks lies in the combination of "horn mouth expansion design" and "copper conductive body". The structure and process need to meet the requirements of wire guidance, scratch resistance, and conductivity stability at the same time.
The application scenarios of horn shaped copper terminal blocks are concentrated in the fields of "multi strand wire connection, batch wiring, and high wire protection requirements", with core coverage of:
Distribution Engineering and Electrical Cabinets:
Low voltage distribution cabinet (civil/industrial): used for connecting 10-50mm ² multi strand copper cables with circuit breakers and contactors, such as adapting 10mm ² multi strand cables to bell shaped terminals, without the need to comb loose wires when inserting, improving the assembly efficiency of the distribution cabinet;
Wiring of Strong Electrical Wells in Buildings: The connection between 25-70mm ² copper busbars and multi strand wires in high-rise residential strong electrical wells, with a horn mouth to protect the insulation layer of the wires and prevent insulation damage caused by wiring pulling.
Industrial equipment and automation:
Motor junction box: used for connecting 16-120mm ² multi strand copper cables to motor terminals, with a horn mouth to prevent copper wire scratches during cable insertion, suitable for motor vibration environments, and to avoid loose wires;
Industrial robot wiring harness: The robot is connected with 6-25mm ² fine specification multi strand wires inside, and the horn mouth facilitates the insertion of wires in narrow spaces while protecting the wires from wear and tear caused by robot movement.
Automotive and Transportation Electrical:
High voltage wiring harness for new energy vehicles: used for connecting 25-185mm ² multi strand copper cables with batteries and inverters. The horn mouth is compatible with automated crimping production lines for automotive wiring harnesses, improving batch production efficiency while protecting the cable insulation layer (withstanding high temperatures inside the car cabin);
Commercial vehicle electrical system: The connection between the 35-70mm ² multi stranded copper wire of trucks and buses and the controller, with a horn mouth to prevent insulation damage caused by friction of the wire under bumpy road conditions.
Precision electronics and medical equipment:
Medical instruments (such as ultrasound equipment and monitors): internal 1.5-4mm ² fine specification multi strand copper wires are connected, and the horn mouth protects the fine copper wires from scratches, ensuring stable transmission of instrument signals;
Communication base station equipment: The connection between 6-10mm ² multi strand copper wires and RF modules in the base station, with silver plated horn terminals and low impedance characteristics, meets the requirements of high-frequency signal transmission, while convenient wiring reduces the difficulty of base station maintenance.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.