HXGN17-12 12kV Box-type metal enclosed ring main unit for urban power grid

  • HXGN17-12 12kV Box-type metal enclosed ring main unit for urban power grid

Key attributes

Brand MV Switchgear Accessories
Model NO. HXGN17-12 12kV Box-type metal enclosed ring main unit for urban power grid
Rated voltage 12kV
Rated normal current 630A
Rated frequency 50/60Hz
Series HXGH17

Product descriptions from the supplier

Description

The HXGN17-12 AC Metal-enclosed Ring Main Unit Switchgear (hereinafter referred to as "ring main unit") is a new product designed and developed by from oversea advanced latest techniques. The technical indicators of the product reaches standard of IEC62271-200 and GB3906. The product is characterized by small volume,light weight,operation flexibility,maintenance convenience, and quality stability & reliability, and it comes out with perfect interlock protection functions and IP3X protecton grade, so it is an ideal product for mains grid reconstruction. The product is mainly applicable to three-phase AC network for receiving and distributing energy.

Mainly applicable in urban power grid construction and renovation project. industrial and mining enterprises.high-rise buildings and communal facilities .For power distribution .controlling and protection on electric equipment as the loop power supply unit or termina equipment. It also can be installed in preloaded substation.

Working Environment

1.Altitude: Not exceed 2500m above sea level

2.Ambient temperature:-25℃ ~ +45℃, the highest temperature is not exceed25℃

3.Ambient humidity: Daily average RH ≤ 95%; Monthly average RH ≤ 90%

4.Earthquake intensity: ≤ 8°

5.No flammable, explosive, no serious pollution, No chemical corrosion and severe vibration.

Technical Parameters

No.

Item

 

Unit

Data

       

FN12-10

FZN25-12

1

Rated voltage

 

kV

12

12

2

Rated current

load break switchgear

A

630

630

Combined switchgear

A

125

125

3

Rated frequency

 

Hz

50

50

4

Rated short-circuit breaking current

 

kA

31.5

31.5

 

Rated short-time withstand current

 

kA

20

20

 

Rated active on-load breaking current

 

A

630

630

5

Rated peak withstand current

 

kA

50

50

6

Rated power frequency voltage withstands inter-phase, to earth and to the open contact

 

kV

42

48

7

Thundering withstands voltage inter-phase, to earth and to the open the contact

 

kV

75

85

8

Mechanical life

 

times

10000

10000

9

Rated take-over current

 

A

3150

3150

10

Protection level

   

IP2X

IP2X

11

Operating mode

   

Manual or automatic

Manual or automatic

12

Control circuit rated voltage

 

V

DC: 110, AC:220

DC: 110, AC:220

FAQ for
Q: Can HXGN17-12 630A Ring Main Unit be customized for special requirements?
A:

Customization options include: ① Adjusting IP protection level (up to IP54 for harsh environments); ② Adding electric/manual operation mode switching; ③ Matching different accessories for box-type substation integration. Contact our technical team with your specific voltage, current, or environmental needs for tailored solutions.

Q: What are the key differences between HXGN17-12 and HXGN15-12 Ring Main Units?
A:

Both are 12kV switchgears, but HXGN17-12 adopts a single-busbar structure with integrated "five-prevention" interlock, more suitable for frequent operation and terminal power supply. HXGN15-12 uses SF6 composite switches with air insulation, focusing on distribution automation expandability. Choose HXGN17-12 for scenarios requiring compact structure and stable interlocking performance.

Q: What is the main application scenario of HXGN17-12 11KV 630A Ring Main Unit?
A:

 It is a fixed metal-enclosed switchgear designed for 3-12kV AC 50/60Hz power systems with rated current ≤630A. Ideal for industrial and mining enterprises, box-type substations, urban power grids, and high-rise building power distribution, it excels in frequent operation scenarios with reliable power control and protection functions.

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Instrument meters/Tester/Production equipment/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Comparative Analysis of High-Voltage Load Switch Technologies
    A load switch is a type of switching device positioned between circuit breakers and disconnectors. It features a simple arc extinguishing device capable of interrupting rated load current and certain overload currents, but cannot interrupt short-circuit currents. Load switches can be classified into high-voltage and low-voltage types according to their operating voltage.Solid gas-producing high-voltage load switch: This type utilizes the energy from the breaking arc itself to cause gas-producing
    12/15/2025
  • Analysis of Faults and Solutions for 17.5kV Ring Main Units in Distribution Networks
    With the improvement of social productivity and people's quality of life, the demand for electricity is continuously increasing. To ensure the effectiveness of power grid system configuration, it is necessary to reasonably construct distribution networks based on actual conditions. However, during the operation of distribution network systems, 17.5kV ring main units play a very important role, so the impact caused by failures is extremely significant. At this point, it is essential to adopt reas
    12/11/2025
  • How to install a DTU on an N2 Insulation ring main unit?
    DTU (Distribution Terminal Unit), a substation terminal in distribution automation systems, is secondary equipment installed in switching stations, distribution rooms, N2 Insulation ring main units (RMUs), and box-type substations. It bridges primary equipment and the distribution automation master station. Older N2 Insulation RMUs without DTUs cannot communicate with the master station, failing to meet automation requirements. While replacing entire RMUs with new DTU-integrated models would sol
    12/11/2025
  • Design of a New 12kV Environmentally Friendly Gas-Insulated Ring Main Unit
    1. Specific Design1.1 Design ConceptState Grid Corporation of China actively promotes grid energy conservation and low-carbon development to achieve national carbon peak (2030) and neutrality (2060) goals. Environmentally friendly gas-insulated ring main units represent this trend. A new 12kV integrated environmentally friendly gas-insulated ring main unit was designed combining vacuum interrupter technology with three-position disconnectors and vacuum circuit breakers. The design utilized Solid
    12/11/2025
  • Integrated Intelligent Ring Main Units in 10kV Distribution Automation
    In the rational application of intelligent technologies, the integrated intelligent ring main unit in 10kV distribution automation construction is more conducive to improving the construction level of 10kV distribution automation and ensuring the stability of 10kV distribution automation construction.1 Research Background Integrated intelligent ring main unit.(1) The integrated intelligent ring main unit adopts more advanced technologies, including but not limited to network technology, communic
    12/10/2025
  • 35kV RMU Busbar Failure Due to Installation Errors Analysis
    This article introduces a case of 35kV ring main unit busbar insulation breakdown failure, analyzes the failure causes and proposes solutions [3], providing reference for the construction and operation of new energy power stations.1 Accident OverviewOn March 17, 2023, a photovoltaic desertification control project site reported a ground fault trip accident in the 35kV ring main unit [4]. The equipment manufacturer arranged a team of technical experts to rush to the site to investigate the cause
    12/10/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.