IMB Series HV outdoor current transformers

  • IMB Series HV outdoor current transformers

Key attributes

Brand Rockwell
Model NO. IMB Series HV outdoor current transformers
Rated voltage 145kV
Series IMB Series

Product descriptions from the supplier

Description

Overview

Main features
● The unique ‘filling’ composition of oil and quartz results in a compact design
● No oil change or filtration required as the expansion chamber / cooler is filled with Nitrogen (N2) / Metal bellows
● All external iron parts are MS painted for protection against detrimental effects of atmosphere and chemicals
● High seismic withstand capability in both vertical and horizontal directions
● Flexible design to meet special customer requirements such as low currents, high burden, creepage and high altitude
● All gaskets are below oil level ensuring positive oil sealing

Primary winding

The hairpin shaped conductor with graded insulation ensures uniform voltage distribution. The winding is insulated with special paper which has high mechanical and dielectric strength as well as low dielectric losses and good resistance to ageing.

Ratio selection is generally achieved through suitable secondary tapping in the secondary winding.

For ratios in multiples up to and including 1500 A (e.g. 1500-750, 1400-700, 1000-500-250, etc.) selection can also be achieved by a reconnectable primary winding. The primary winding is divided into equal parts, which can be connected in series or parallel by means of external links on the connection head.

The Short Time Current (STC) rating is as per series connection of primary winding (i.e. minimum cross section). With a parallel connection, the STC rating is therefore doubled.

The primary winding consists of a tube open at both ends allowing the oil to circulate. The heat losses are dissipated in the expansion chamber/cooler.

Tan Delta measuring terminal (D3/F terminal)

The outer shield of primary insulation is connected to a bushing in the secondary terminal box and earthed. This is designated as D3/F terminal.

This Tan Delta (D3/F) terminal must be earthed before the CT is charged.

Core

The Current Transformers can normally accommodate up to five cores. However more cores can also be provided on request. High-grade-silicon-steel CRGO is used for manufacture of cores. Stringent accuracy requirements of metering cores are achieved by using special cores made from nickel-iron alloy.

High grade enameled wires are used for winding secondary turns on the cores. They are evenly distributed across the periphery of the core, reducing leakage reactance to a minimum.

Tank & insulator

The lower portion of the CT consists of a aluminium or MS painted tank in which the cores are positioned around the straight limb primary winding. The upper portion of the transformer consists of high-grade brown glazed insulator made from porcelain or polymer. The gaskets are made of oil-proof material.

Technology paramete

 

Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 60000m² Total staff: Highest Annual Export(usD): 100000000
Workplace: 60000m²
Total staff:
Highest Annual Export(usD): 100000000
Services
Business Type: Design/Manufacture/Sales
Main Categories: High Voltage Electrical Apparatus/Electric transformer
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026

Related Solutions

Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.