Indoor vacuum circuit breaker Generator circuit breaker up to 63kA and 15 kV

  • Indoor vacuum circuit breaker Generator circuit breaker up to 63kA and 15 kV

Key attributes

Brand ABB
Model NO. VD4G generator circuit breaker Small footprint, full protection for generator applications
Rated voltage 15kV
Rated normal current 1250A
Rated frequency 50/60Hz
Series VD4G

Product descriptions from the supplier

Description

Description:

ABB offers its new vacuumgenerator circuit breakers at 15 kV,4000 A, 63 kA in accordance to thenew Dual Logo IEEE/IEC 62271-37-013 standard to satisfy yourbusiness needs in power generation applications.

Features:

Protect your assets

  • Use a solution completely inaccordance with the latest global standards - IEC as well as IEEE

  • Count on a generator circuit breakersuitable for all highly demanding conditions, including out-of-phase condition and island mode

  • Be safe thanks to a completely testedsolution for DC-component up to130%, so no need to add any time delay in the protection

Maximize your output

  • Experience the easy installation/integration of VD4G, thanks to itsinterfaces and dimensions equivalentto the standard version VD4

  • Accelerate your projects with theoutstanding technical support grantedby our Field Application Engineeringm team

Optimize your investment

  • Choose ratings that fit your needs from 25/16 kA @ 15 kV to 63/50 kA @ 15 kV

  • Take advantage of using the samecompact switchgear setup like inpower distribution systems

Technical characteristics:

Standards IEEE/IEC 62271-37- 013

 

Documentation Resource Library
Public.
VD4G generator circuit breaker Small footprint, full protection for generator applications
Catalogue
English
FAQ for
Q: What is a generator circuit breaker?
A: A generator circuit breaker (GCB) is a specialized switchgear device used in power generation systems to safely connect or disconnect a generator from the electrical grid or load. It is designed to interrupt high fault currents, protect the generator from overloads, short circuits, and other electrical faults, and ensure reliable operation during normal and abnormal conditions.
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 20000m² Total staff: Highest Annual Export(usD): 580000000
Workplace: 20000m²
Total staff:
Highest Annual Export(usD): 580000000
Services
Business Type: Sales
Main Categories: High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • HECI GCB for Generators – Fast SF6 Circuit Breaker
    1.Definition and Function1.1 Role of the Generator Circuit BreakerThe Generator Circuit Breaker (GCB) is a controllable disconnect point located between the generator and the step-up transformer, serving as an interface between the generator and the power grid. Its primary functions include isolating generator-side faults and enabling operational control during generator synchronization and grid connection. The operating principle of a GCB is not significantly different from that of a standard c
    01/06/2026
  • 300MW+ Unit Generator Circuit Breaker Automatic Tripping: Causes, Phenomena & Handling Measures
    Units with a capacity of 300MW and above are usually connected in a generator-transformer unit configuration and connected to the power system through the circuit breaker on the high-voltage side of the transformer. During the normal operation of the unit, the circuit breaker may trip automatically due to various reasons. Operators must make correct judgments and take timely measures to ensure the safe operation of the unit.1. Causes of Automatic Circuit Breaker Tripping Tripping due to relay pr
    11/27/2025
  • Chinese GCB makers developed complete sets for 1GW unit applications.
    Recently, a Chinese generator circuit breaker manufacturer has successfully developed generator circuit breakers for 1,000MW hydropower and thermal power units, which have passed the group's appraisal and acceptance. Their comprehensive performance has reached the international leading level, filling the domestic gap. This is another major breakthrough following the group's mastery of the technology for large-capacity generator circuit breaker complete sets for 400MW, 600MW, and 800MW units, mar
    11/26/2025
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.