• KW2011 Series transformer transformation ratio tester
KW2011 Series transformer transformation ratio tester
discuss personally
Model
KW2011
Basic info
Brand Wone Store
Model NO. KW2011 Series transformer transformation ratio tester
Rated voltage 220V
Rated capacity 10kVA
Series KW2011 Series
Product Detail

Overview

  • According to IEC and relevant national regulations, the semi-finished and finished products during the production process of transformers, as well as newly installed and overhauled transformers, must undergo transformation ratio testing before being put into operation. In the "Handover and Preventive Test Regulations for Electrical Equipment", it is also required to regularly determine the transformation ratio of operating transformers. The transformation ratio test of transformers can check the windings, tap-changers of transformers, judge the status, and determine whether there are defects such as turn-to-turn short circuits, connection errors, and inter-turn short circuits in transformers, thus ensuring the safe use of equipment.

  • The transformer transformation ratio tester developed and produced by our company uses a 32-bit ARM core as the processing core to control the entire machine. It realizes one-time completion of the transformation ratio measurement of single-phase or three-phase transformers. The operation of the tester uses a Chinese menu display, which is simple and intuitive. The test results are accurate and reliable, and can store and print the test results. It has strong anti-interference ability and can meet the needs of various large, medium and small transformer transformation ratio tests. The instrument can directly work using the internal battery, which greatly facilitates the use of field workers.

  • Fast testing speed, high precision, and good repeatability.

  • It has the test function for PT and Z-connected transformers.

  • It can automatically test the transformation ratio and tap number.

  • One start can automatically measure the turns ratio of windings and calculate parameters such as transformation ratio error, tap position, tap value, and polarity.

  • It can automatically store the measurement results. This instrument has a built-in non-volatile memory and a micro printer, and can print all data.

  • Large LCD Chinese menu display, the operation is intuitive and convenient.

  • The instrument is small and lightweight, suitable for field operations.

Parameters

Project

Parameters

Power input

Rated voltage

AC 220V±10% 50Hz

Power Input

2-phase 3-wire

power output

Rated capacity

10kVA

output voltage

0~10kv(current Max. 1A)

output current

0-600A

CT rate measurement

Range

≤2000A/1A

precision

≤0.5%

VT rate

measurement

Range

≤5000kV

precision

≤0.5%

Excitation measurement accuracy

≤0.5%

Operating temperature

-10℃-40℃

Size

345mmx245mmx225mm

Weight

4kg

 

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
What safety protection facilities are there in the transformer body structure?
What safety protection facilities are there in the transformer body structure?
Transformer Main Body Construction and Safety Protection DevicesA power transformer is equipped with several critical safety protection devices to ensure reliable and safe operation. These components play essential roles in monitoring, protecting, and maintaining the integrity of the transformer under varying operating conditions.1. Oil Cushion (Conservator Tank)The oil cushion, also known as the conservator tank, typically has a capacity of approximately 8–10% of the total transformer oil
Rockwell
08/09/2025
Analysis on Live Testing of 10kV SF₆ Ring Main Units
Analysis on Live Testing of 10kV SF₆ Ring Main Units
1 Live Testing AnalysisDetection of Issues through Live TestingIn October of a certain year, during live partial discharge (PD) testing on 10kV ring main units (RMUs) under our jurisdiction, the maintenance and testing team observed significantly elevated signal amplitudes in several units (Transient Earth Voltage (TEV) readings around 18 dB, and ultrasonic readings around 20 dB). Most of these units were from the same manufacturer. Consequently, a unified test was conducted on 15 RMUs from this
Oliver Watts
08/09/2025
Analysis of Two Faults in 10kV SF6 Ring Main Units
Analysis of Two Faults in 10kV SF6 Ring Main Units
1. Introduction to 10kV SF6 Ring Main Units (RMUs)A 10kV SF6 ring main unit typically consists of three main parts: the gas compartment (tank), the operating mechanism compartment, and the cable connection compartment.The gas compartment is the core component of the RMU. It is filled with SF6 gas and houses critical elements such as the load switch, busbars, and switch shaft. The load switch features a three-position design—comprising closing, opening, and grounding functions—and is
Felix Spark
08/09/2025
A Brief Analysis of Technical Issues in SF6 Fully Insulated Gas-Insulated Ring Main Units
A Brief Analysis of Technical Issues in SF6 Fully Insulated Gas-Insulated Ring Main Units
SF6 Fully Insulated Gas-Insulated Ring Main Units (hereinafter referred to as RMUs) primarily consist of load switch units and high-voltage AC load switch-fuse combination appliances (hereinafter referred to as combination appliances). Depending on user requirements, they can be configured as either common-tank or unitized structures.In practical engineering applications, electrical connections are typically established using either top-mounted solid-insulated busbars or side-mounted plug-in bus
Ron
08/09/2025
Advantages of SF6 Fully Insulated Ring Main Units in Power Supply Systems
Advantages of SF6 Fully Insulated Ring Main Units in Power Supply Systems
Current Power Supply Method Using SF6 Ring Main UnitsTo enhance grid performance, the design of traditional SF6 ring main units (RMUs) has been further optimized. A key feature of second-generation SF6 RMUs is the use of a grounded, enclosed epoxy resin housing, with SF6 gas as the insulating medium. Two three-position load switches and one three-position arc-rotating circuit breaker are integrated into a single sealed unit, equipped with a pressure relief safety valve. In the event of arc-quenc
Echo
08/09/2025
What types of transformer voltage regulation are there?
What types of transformer voltage regulation are there?
Transformer voltage regulation can be achieved through on-load tap changing (OLTC) and off-load tap changing:On-load voltage regulation allows the transformer to adjust its tap position while in operation, thereby changing the turns ratio to regulate voltage. There are two methods: line-end regulation and neutral-point regulation. Line-end regulation involves placing the tap on the line end of the high-voltage winding, whereas neutral-point regulation places the tap on the neutral end of the hig
Vziman
08/09/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!