• KWDY-420 Series Noise testing balanced load system
KWDY-420 Series Noise testing balanced load system
discuss personally
Model
KWDY-420
Basic info
Brand Wone Store
Model NO. KWDY-420 Series Noise testing balanced load system
Rated voltage 380V
Rated normal current 160A
Rated Output Rating 100kw
Series KWDY-420 Series
Product Detail

Overview

The system is equipped with a touch - screen control operation device. Testers can complete operations such as digital power switching, digital power output adjustment, compensating reactor group switching, total output switching, and emergency stop through the embedded touch - operated human - machine interface in cooperation with the PLC programmable logic controller. At the same time, they can view the three - phase voltage and current of the system input, digital power output, and total output.

The digital power supply equipped in the system has a fully digital structure. Its output adjustment is accurate and linear, the output power quality is high and not affected by the power quality of the input side, and the frequency output is stable. When the load of the digital power supply changes within 20% - 100%, the power factor on the power supply side reaches 0.96. It has a low demand for power capacity and does not need to add a harmonic suppression device when the power quality is poor. At the same time, the harmonics generated by the digital power supply on the power supply side are less than 2%, which will not affect the operation of other devices in the network. The digital power supply has complete hardware protection measures. Its electronic protection method has a fast execution speed and has multiple protection measures such as power device overload fault protection, over - current fault protection, over - voltage fault protection, phase - loss fault protection, short - circuit fault protection, and over - temperature fault protection. There are also zero - start voltage - rising protection and automatic zero - return functions set in the system.

The three - phase compensating reactors equipped in the system have a rated voltage of 400V, with capacities of 50kvar, 100kvar, and 200kvar respectively. There are 3 reactors in total with a total capacity of 350kVar. The full - load operation time can meet more than 30 minutes, and the contactor controls the combined switching of the 3 reactors.

Parameters

Project

Parameters

Power input

Rated voltage

AC 380V±10% 50Hz

Rated current

160A

Power Input

3-phase 4-wire

Controller

Rated

Output voltage

3-phase 0~400V(≤600A)

Output waveform

pure sine wave

Voltage regulation accuracy

2V/60s

Load capacity

≤140A

Power frequency withstand voltage

2000V/min

Operating temperature

-10℃-50℃

 

Know your supplier
Wone Store
Main Categories
High Voltage Electrical Apparatus/Low Voltage Electrical Apparatus/Wire cable/Instrument meters/New energy/Tester/Production equipment/Generator/Electrical fittings/Integrated Electrical Equipment/Instrument Transformer/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Knowledges
What safety protection facilities are there in the transformer body structure?
What safety protection facilities are there in the transformer body structure?
Transformer Main Body Construction and Safety Protection DevicesA power transformer is equipped with several critical safety protection devices to ensure reliable and safe operation. These components play essential roles in monitoring, protecting, and maintaining the integrity of the transformer under varying operating conditions.1. Oil Cushion (Conservator Tank)The oil cushion, also known as the conservator tank, typically has a capacity of approximately 8–10% of the total transformer oil
Rockwell
08/09/2025
Analysis on Live Testing of 10kV SF₆ Ring Main Units
Analysis on Live Testing of 10kV SF₆ Ring Main Units
1 Live Testing AnalysisDetection of Issues through Live TestingIn October of a certain year, during live partial discharge (PD) testing on 10kV ring main units (RMUs) under our jurisdiction, the maintenance and testing team observed significantly elevated signal amplitudes in several units (Transient Earth Voltage (TEV) readings around 18 dB, and ultrasonic readings around 20 dB). Most of these units were from the same manufacturer. Consequently, a unified test was conducted on 15 RMUs from this
Oliver Watts
08/09/2025
Analysis of Two Faults in 10kV SF6 Ring Main Units
Analysis of Two Faults in 10kV SF6 Ring Main Units
1. Introduction to 10kV SF6 Ring Main Units (RMUs)A 10kV SF6 ring main unit typically consists of three main parts: the gas compartment (tank), the operating mechanism compartment, and the cable connection compartment.The gas compartment is the core component of the RMU. It is filled with SF6 gas and houses critical elements such as the load switch, busbars, and switch shaft. The load switch features a three-position design—comprising closing, opening, and grounding functions—and is
Felix Spark
08/09/2025
A Brief Analysis of Technical Issues in SF6 Fully Insulated Gas-Insulated Ring Main Units
A Brief Analysis of Technical Issues in SF6 Fully Insulated Gas-Insulated Ring Main Units
SF6 Fully Insulated Gas-Insulated Ring Main Units (hereinafter referred to as RMUs) primarily consist of load switch units and high-voltage AC load switch-fuse combination appliances (hereinafter referred to as combination appliances). Depending on user requirements, they can be configured as either common-tank or unitized structures.In practical engineering applications, electrical connections are typically established using either top-mounted solid-insulated busbars or side-mounted plug-in bus
Ron
08/09/2025
Advantages of SF6 Fully Insulated Ring Main Units in Power Supply Systems
Advantages of SF6 Fully Insulated Ring Main Units in Power Supply Systems
Current Power Supply Method Using SF6 Ring Main UnitsTo enhance grid performance, the design of traditional SF6 ring main units (RMUs) has been further optimized. A key feature of second-generation SF6 RMUs is the use of a grounded, enclosed epoxy resin housing, with SF6 gas as the insulating medium. Two three-position load switches and one three-position arc-rotating circuit breaker are integrated into a single sealed unit, equipped with a pressure relief safety valve. In the event of arc-quenc
Echo
08/09/2025
What types of transformer voltage regulation are there?
What types of transformer voltage regulation are there?
Transformer voltage regulation can be achieved through on-load tap changing (OLTC) and off-load tap changing:On-load voltage regulation allows the transformer to adjust its tap position while in operation, thereby changing the turns ratio to regulate voltage. There are two methods: line-end regulation and neutral-point regulation. Line-end regulation involves placing the tap on the line end of the high-voltage winding, whereas neutral-point regulation places the tap on the neutral end of the hig
Vziman
08/09/2025
×