• Elbow Type Connector
Elbow Type Connector
discuss personally
Model
RW-PTZT-35/200A
RW-PTZT-24/200A
RW-PTZT-12/200A
Basic info
Brand Switchgear parts
Model NO. Elbow Type Connector
Rated voltage 35kV
Rated normal current 200A
Series RW-PTZT
Product Detail

Summary
Separable connector is fully insulated, fully sealed connector, is widely used in outdoor power distribution Transformer, American cabinet type transformer, ring main unit and cable branch box, buried transformers and other electrical equipments.lt can be installed on outgoing line of 200A T type connector,20oA Busbar,single-pass (Double type) apparatus bushing and load conversion connector of American cabinet type transformer. Test points can be installed live monitor, in order to check the charged state of the equipment, but also to meet the nuclear phase requirements. Conductive rod connector arc extinguishing material, it can be charged in the state operation, but can not cut offthe short-circuit current; can be used as the load switch to open the current 200A. Applicable for XLPE cable cross-section 25mm²~400mm²

15kV Model & Specification

Model & Specification

Applicable highest voltage

Rated current

Cross - section of cable mm²

Applicable range of Outside diameter of insulation of cable mm²

PTZT - 15/200 - 35

8.7/15kV

200A

35

Φ23.1 - Φ27.1

PTZT - 15/200 - 50

8.7/15kV

200A

50

Φ14.1 - Φ23.1

PTZT - 15/200 - 70

8.7/15kV

200A

70

Φ16.3 - Φ25.7

PTZT - 15/200 - 95

8.7/15kV

200A

95

Φ21.3 - Φ28.2

PTZT - 15/200 - 120

8.7/15kV

200A

120

Φ21.3 - Φ28.2

PTZT - 15/200 - 150

8.7/15kV

200A

150

Φ21.3 - Φ28.2

25kV Model & Specification

Model & Specification

Applicable highest voltage

Rated current

Cross - section of cable  mm²

Applicable range of Outside diameter of insulation of cable    mm²

PTZT - 25/200 - 50

18/20kV

200A

50

Φ23.1 - Φ27.1

PTZT - 25/200 - 70

18/20kV

200A

70

Φ24.9 - Φ29.0

PTZT - 25/200 - 95

18/20kV

200A

95

Φ27.4 - Φ32.5

PTZT - 25/200 - 120

18/20kV

200A

120

Φ27.4 - Φ32.5

PTZT - 25/200 - 150

18/20kV

200A

150

Φ31.0 - Φ36.1

35kV Model & Specification

Model & Specification

Applicable highest voltage

Rated current

Cross-section of cable  mm²

Applicable range of Outside diameter of insulation of cable   mm²

PTZT-35/200-50

26/35kV

200A

50

Φ29.5 - Φ33.1

PTZT-35/200-70

26/35kV

200A

70

Φ32.5 - Φ35.4

PTZT-35/200-95

26/35kV

200A

95

Φ34.4 - Φ38.6

PTZT-35/200-120

26/35kV

200A

120

Φ34.4 - Φ38.6

PTZT-35/200-150

26/35kV

200A

150

Φ37.7 - Φ40.5

Know your supplier
Switchgear parts
VoltEdge Solutions​​ specializes in manufacturing premium ​​MV switchgear accessories​​ for global power distribution systems. Our product range includes circuit breaker modules, disconnector spares, and surge arrestors, engineered for ​​24kV+ substations​​ and renewable energy plants. With ISO-certified production and 24/7 technical support, we ensure ​​reliability, compliance​​ with IEC standards, and rapid global supply.
Main Categories
Electrical fittings/Equipment Parts
Business Type
Sales
Highest Annual Export (USD)
$300000000
Professional Experience
1 years
Workplace
1000m²
占位
占位
Related Products
Related Knowledges
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
Key Points of Online Monitoring Technology for Zinc Oxide Surge Arresters
1 Architecture of the Online Monitoring System for Zinc Oxide Surge ArrestersThe online monitoring system for zinc oxide surge arresters comprises three layers: the station control layer, bay layer, and process layer.Station Control Layer: Includes a monitoring center, a Global Positioning System (GPS) clock, and a B - code clock source.Bay Layer: Consists of online monitoring Intelligent Electronic Devices (IEDs).Process Layer: Features monitoring terminals for Potential Transformers (PTs) and
Oliver Watts
07/30/2025
Improvement and Application of the Test Device for Surge Arrester Online Monitor
Improvement and Application of the Test Device for Surge Arrester Online Monitor
1 Significance of Surge Arrester Online Monitors1.1 Enhance Power System Safety, Reduce Lightning DamageDuring lightning strikes, surge arresters play a core role in discharging overvoltage. Online monitors ensure arrester stability, detect potential faults in real - time, and trigger alarms for timely intervention—effectively reducing lightning - induced damage to power equipment and systems, and maintaining stable operation.1.2 Real - Time Status Monitoring, Improve Maintenance Efficienc
Edwiin
07/30/2025
Design of Monitoring System for Surge Arrester in GIS Cubicle of 10kV Power Distribution System for High-Speed Railways
Design of Monitoring System for Surge Arrester in GIS Cubicle of 10kV Power Distribution System for High-Speed Railways
1 Research BackgroundMetal - oxide surge arresters, sealed in cabinets, bear system voltage continuously, risking aging failures, even breakdowns/explosions causing electrical fires. Thus, regular inspection/maintenance is needed. Traditional 3–5 - year - cycle detection (power cut, arrester removal for tests; reinstallation if replaced) poses safety risks and faces space/environment - based standard - grasping difficulties.2 Monitoring Principle of 10kV GIS Cabinet Surge ArresterTo ensure
Dyson
07/30/2025
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a power transformer designed for 50Hz operate normally at a frequency of 60Hz?
Can a 50Hz-Designed Power Transformer Operate on 60Hz Grid?If a power transformer is designed and built for 50Hz, can it run on a 60Hz grid? If so, how do its key performance parameters change?Key Parameter ChangesShort-Circuit Impedance:For a given transformer (same voltage and capacity), short-circuit impedance is proportional to frequency. Thus, a 50Hz-designed unit operating at 60Hz sees a 20% increase—higher frequency intensifies alternating leakage field opposition to current.No-Load
Vziman
07/29/2025
What are the common faults of overhead cables?
What are the common faults of overhead cables?
Overhead cables, due to their exposure to external environments, are subject to various influences that can lead to different types of faults. Below are some common types of faults in overhead cables and their causes:1. Mechanical DamageCaused by external forces such as falling trees, vehicle collisions, or construction accidents.Prolonged vibrations or swinging can also cause material fatigue in cables.2. Weather-Related FaultsLightning Strikes: Direct hits or nearby lightning strikes can cause
Felix Spark
07/29/2025
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
An Innovative Photoelectromagnetic Cable Eccentricity Measuring Instrument
A core challenge in online cable eccentricity measurement is the cable’s high - speed motion. This requires non - contact measurement equipment that can handle cable jitter. X - ray cable eccentricimeters, based on optical transmission imaging, measure multi - layer contour dimensions to calculate the geometric center of conductors relative to insulation eccentricity. However, they have drawbacks: slow measurement speed (only a few times per second), increased errors from cable jitter, and
Oliver Watts
07/29/2025
×
Inquiry
Download
IEE-Business is dedicated to serving the personnel in the global power industry.
Join IEE-Business, not only can you discover power equipment and power knowledge, but also canhnd like - minded friends!