GRL8-01 02 Level Control Relay

  • GRL8-01 02 Level Control Relay
  • GRL8-01 02 Level Control Relay

Key attributes

Brand Switchgear parts
Model NO. Level Control Relay GRL8-01 02
Rated frequency 50/60Hz
Series GRL8

Product descriptions from the supplier

Description

The GRL8-01/02 series is an intelligent control relay designed specifically for liquid level monitoring, utilizing isolated power supply technology and modular structure. Its compact 18mm width body supports 35mm standard card rail installation, suitable for automation control scenarios of various liquid storage and transportation systems.

GRL8-01/02 series liquid level control relay product features:
1. Dual mode flexible configuration
Type 01 supports 2-pole liquid level control
Type 02 supports 2-pole or 2-pole liquid level control
2. Programmable working mode
Free selection of drainage mode (triggered by high liquid level) or water supply mode (triggered by low liquid level) through dip switch
3. Precision parameter adjustment
Sensitivity 5-100k Ω continuously adjustable, suitable for liquids with different conductivities
The action delay can be set between 0.1s-10s, effectively suppressing interference from liquid level fluctuations
4. Wide voltage compatible design
Supports AC/DC 24~240V wide input, isolated power supply enhances system safety
5. Visual state management
Two color LED indicator lights display real-time power supply status and relay action signals
6. Industrial grade compact structure
35mm rail installation in accordance with DIN EN 60715 standard, 18mm ultra-thin width saves control cabinet space

Advantages of GRL8-01/02 series liquid level control relay products:
1. Multi purpose: A single device is compatible with both water supply and drainage modes, reducing the variety of spare parts
2. Anti interference design: adjustable delay function effectively filters false signals and improves action reliability
3. Strong compatibility: wide voltage input+wide impedance range suitable for mainstream liquid level sensors worldwide
4. Convenient maintenance: Modular plug-in design supports quick on-site replacement, LED dual indication reduces the difficulty of fault diagnosis
5. Security Enhancement: The isolated power supply design prevents induced electrical interference and complies with industrial control safety standards

Technical parameters GRL8-01 GRL8-02
Function 2 level contorl mode 2 or 1 level contorl mode
Supply terminals A1-A2
Voltage range AC/DC 24-240V(50-60Hz)
Input max.2VA
Supply voltage tolerance -15%;+10%
Sensitivity ( input resistance) adjustable in range 5 kΩ -100 kΩ
Voltage in electrodes max. AC 5 V
Current in probe AC <0.1 mA
Time response max. 400 ms
Max. capacity length 800 m (sensitivity 25k&Omega;), 200 m (sensitivity 100 k&Omega;)
Max. capacity of probe cable 400 nF (sensitivity 25k&Omega;), 100 nF (sensitivity 100 k&Omega;)
Time delay (t) adjustable, 0.1 -10 s
Accuracy in setting (mechanical) &plusmn; 10 %
Temperature coefficient 0.05%/℃,at=20℃(0.05%℉,at=68℉)
Output 1&times;SPDT
Current rating 1&times;10A(AC1)
Switching voltage 250VAC/24VDC
Min.breaking capacity DC 500mW
Output indication red LED
Mechanical life 1&times;107
Electrical life(AC1) 1&times;105
Reset time max.200ms
Operating temperature -20℃ to+55℃(-4℉to131℉)
Storage temperature -35℃ to+75℃(-22℉to158℉)
Mounting/DIN rail Din rail EN/IEC 60715
Protection degree IP40 for front panel/IP20 terminals
Operating position any
Overvoltage cathegory III.
Pollution degree 2
Max.cable size(mm 2) solid wire max.1&times;2.5or 2&times;1.5/with sleeve max.1&times;2.5(AWG 12)
Tightening torque 0.8Nm
Dimensions 90&times;18&times;64mm
Weight 70g 72g
Standards EN 60255-1
Know your supplier
Online store
On-time delivery rate
Response time
100.0%
≤4h
Company overview
Workplace: 1000m² Total staff: Highest Annual Export(usD): 300000000
Workplace: 1000m²
Total staff:
Highest Annual Export(usD): 300000000
Services
Business Type: Sales
Main Categories: Low Voltage Electrical Apparatus/Instrument meters/Production equipment/Tester/High Voltage Electrical Apparatus/Electrical fittings/Equipment Parts
Whole life care manager
Whole-life care management services for equipment procurement, use, maintenance, and after-sales, ensuring safe operation of electrical equipment, continuous control, and worry-free electricity consumption.
The equipment supplier has passed platform qualification certification and technical evaluation, ensuring compliance, professionalism, and reliability from the source.

Related Products

Related Knowledges

  • Faults and Handling of Single-phase Grounding in 10kV Distribution Lines
    Characteristics and Detection Devices for Single-Phase Ground Faults1. Characteristics of Single-Phase Ground FaultsCentral Alarm Signals:The warning bell rings, and the indicator lamp labeled “Ground Fault on [X] kV Bus Section [Y]” illuminates. In systems with a Petersen coil (arc suppression coil) grounding the neutral point, the “Petersen Coil Operated” indicator also lights up.Insulation Monitoring Voltmeter Indications:The voltage of the faulted phase decreases (in
    01/30/2026
  • Neutral point grounding operation mode for 110kV~220kV power grid transformers
    The arrangement of neutral point grounding operation modes for 110kV~220kV power grid transformers shall meet the insulation withstand requirements of transformer neutral points, and shall also strive to keep the zero-sequence impedance of substations basically unchanged, while ensuring that the zero-sequence comprehensive impedance at any short-circuit point in the system does not exceed three times the positive-sequence comprehensive impedance.For 220kV and 110kV transformers in new constructi
    01/29/2026
  • Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?
    Why Do Substations Use Stones, Gravel, Pebbles, and Crushed Rock?In substations, equipment such as power and distribution transformers, transmission lines, voltage transformers, current transformers, and disconnect switches all require grounding. Beyond grounding, we will now explore in depth why gravel and crushed stone are commonly used in substations. Though they appear ordinary, these stones play a critical safety and functional role.In substation grounding design—especially when multiple gr
    01/29/2026
  • Why Must a Transformer Core Be Grounded at Only One Point? Isn't Multi-Point Grounding More Reliable?
    Why Does the Transformer Core Need to Be Grounded?During operation, the transformer core, along with the metal structures, parts, and components that fix the core and windings, are all situated in a strong electric field. Under the influence of this electric field, they acquire a relatively high potential with respect to ground. If the core is not grounded, a potential difference will exist between the core and the grounded clamping structures and tank, which may lead to intermittent discharge.I
    01/29/2026
  • Understanding Transformer Neutral Grounding
    I. What is a Neutral Point?In transformers and generators, the neutral point is a specific point in the winding where the absolute voltage between this point and each external terminal is equal. In the diagram below, pointOrepresents the neutral point.II. Why Does the Neutral Point Need Grounding?The electrical connection method between the neutral point and earth in a three-phase AC power system is called theneutral grounding method. This grounding method directly affects:The safety, reliabilit
    01/29/2026
  • What’s the Difference Between Rectifier Transformers and Power Transformers?
    What is a Rectifier Transformer?"Power conversion" is a general term encompassing rectification, inversion, and frequency conversion, with rectification being the most widely used among them. Rectifier equipment converts input AC power into DC output through rectification and filtering. A rectifier transformer serves as the power supply transformer for such rectifier equipment. In industrial applications, most DC power supplies are obtained by combining a rectifier transformer with rectifier equ
    01/29/2026
Haven't found the right supplier yet? Let matching verified suppliers find you. Get Quotation Now
Haven't found the right supplier yet? Let matching verified suppliers find you.
Get Quotation Now
Send inquiry
+86
Click to upload file
Download
Get the IEE Business Application
Use the IEE-Business app to find equipment, obtain solutions, connect with experts, and participate in industry collaboration anytime, anywhere—fully supporting the development of your power projects and business.